Biblioteca Hospital 12 de Octubre

Cavo-tricuspid isthmus radiofrequency ablation using a novel remote navigation catheter system in patients with typical atrial flutter. (Registro nro. 8222)

000 -CABECERA
Campo de control de longitud fija 02446na a2200325 4500
003 - IDENTIFICADOR DEL NÚMERO DE CONTROL
Campo de control PC8222
005 - FECHA Y HORA DE LA ÚLTIMA TRANSACCIÓN
Campo de control 20210706062655.0
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA
Campo de control de longitud fija 130622s2013 xxx||||| |||| 00| 0 eng d
040 ## - FUENTE DE LA CATALOGACIÓN
Centro transcriptor H12O
041 ## - CÓDIGO DE LENGUA
Código de lengua del texto/banda sonora o título independiente eng
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
Nombre de persona Arribas Ynsaurriaga, Fernando
9 (RLIN) 1249
Término indicativo de función Cardiología
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
Nombre de persona Fontenla Cerezuela, Adolfo
9 (RLIN) 2225
Término indicativo de función Cardiología
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
Nombre de persona López Gil, María
9 (RLIN) 1253
Término indicativo de función Cardiología
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
Nombre de persona Mejía Martínez, Elena
9 (RLIN) 234
Término indicativo de función Instituto Investigación i+12
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
Nombre de persona Salgado Aranda, Ricardo
9 (RLIN) 235
Término indicativo de función Cardiología
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
Nombre de persona Salguero Bodes, Rafael
9 (RLIN) 158
Término indicativo de función Cardiología
245 00 - MENCIÓN DE TÍTULO
Título Cavo-tricuspid isthmus radiofrequency ablation using a novel remote navigation catheter system in patients with typical atrial flutter.
Tipo de material [artículo]
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Nombre del editor distribuidor etc. Europace: European pacing, arrhythmias, and cardiac electrophysiology: journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology,
Fecha de publicación distribución etc. 2014
300 ## - DESCRIPCIÓN FÍSICA
Extensión 16(4):558-62.
500 ## - NOTA GENERAL
Nota general Formato Vancouver:
López-Gil M, Salgado R, Merino JL, Datino T, Figueroa J, Arenal A et al. Cavo-tricuspid isthmus radiofrequency ablation using a novel remote navigation catheter system in patients with typical atrial flutter. Europace. 2014 Apr;16(4):558-62.
501 ## - NOTA DE “CON”
Nota de "Con" PMID: 24058180
504 ## - NOTA DE BIBLIOGRAFÍA; ETC.
Nota de bibliografía etc. Contiene 18 referencias
520 ## - NOTA DE SUMARIO; ETC.
Sumario etc. AIMS: A new remote catheter system (AMIGO™ Remote Catheter System) compatible with conventional ablation catheters is now commercially available but no data about its performance in clinical use during ablation have been reported. This study evaluates the feasibility, efficacy, and safety of cavo-tricuspid isthmus (CTI) ablation with this system in patients with typical atrial flutter (AFl).METHODS AND RESULTS: Sixty patients with typical AFl underwent CTI ablation using the new remote catheter navigation system with 8 mm tip or irrigated catheters in three centres following each centre's routine practice. The endpoint was stable bidirectional CTI block. CTI ablation was successful in 98% of patients. Ablation was completed manually in one patient. The overall procedure, fluoroscopy, and radiofrequency times (median ± standard deviation, range) were 123 ± 42 (50-250), 24 ± 13 (3-82), and 10 ± 8 (1.17-43.3) min, respectively. Three patients had vascular complications not requiring surgical intervention. There were no complications related to the remote catheter manipulation system.CONCLUSION: Cavo-tricuspid isthmus ablation for typical AFl can be safely and effectively performed with the AMIGO™. The learning curve seems to be short even for physicians with limited ablation experience.
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD
9 (RLIN) 119
Nombre de entidad o nombre de jurisdicción como elemento inicial Servicio de Cardiología
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD
9 (RLIN) 625
Nombre de entidad o nombre de jurisdicción como elemento inicial Instituto de Investigación imas12
856 ## - LOCALIZACIÓN Y ACCESO ELECTRÓNICOS
Identificador Uniforme del Recurso (URI) http://pc-h12o-es.m-hdoct.a17.csinet.es/pdf/pc/8/pc8222.pdf
Acceso Solicitar documento
942 ## - ENTRADA PARA ELEMENTOS AGREGADOS (KOHA)
Suprimido en OPAC Público
Fuente de clasificación o esquema de ordenación en estanterías
Koha [por defecto] tipo de item Artículo
Existencias
Suprimido Estado de pérdida Fuente de clasificación o esquema de ordenación en estanterías Estropeado No para préstamo Localización permanente Localización actual Fecha de adquisición Signatura completa Fecha última consulta Fecha del precio de reemplazo Tipo de item de Koha
          Hospital Universitario 12 de Octubre Hospital Universitario 12 de Octubre 2020-01-14 PC8222 2020-01-14 2020-01-14 Artículo

Con tecnología Koha