Biblioteca Hospital 12 de Octubre
Vista normal Vista MARC Vista ISBD

Cavo-tricuspid isthmus radiofrequency ablation using a novel remote navigation catheter system in patients with typical atrial flutter. [artículo]

Por: Arribas Ynsaurriaga, Fernando [Cardiología] | Fontenla Cerezuela, Adolfo [Cardiología] | López Gil, María [Cardiología] | Mejía Martínez, Elena [Instituto Investigación i+12] | Salgado Aranda, Ricardo [Cardiología] | Salguero Bodes, Rafael [Cardiología].
Colaborador(es): Servicio de Cardiología | Instituto de Investigación imas12.
Editor: Europace: European pacing, arrhythmias, and cardiac electrophysiology: journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology, 2014Descripción: 16(4):558-62.Recursos en línea: Solicitar documento Resumen: AIMS: A new remote catheter system (AMIGO™ Remote Catheter System) compatible with conventional ablation catheters is now commercially available but no data about its performance in clinical use during ablation have been reported. This study evaluates the feasibility, efficacy, and safety of cavo-tricuspid isthmus (CTI) ablation with this system in patients with typical atrial flutter (AFl).METHODS AND RESULTS: Sixty patients with typical AFl underwent CTI ablation using the new remote catheter navigation system with 8 mm tip or irrigated catheters in three centres following each centre's routine practice. The endpoint was stable bidirectional CTI block. CTI ablation was successful in 98% of patients. Ablation was completed manually in one patient. The overall procedure, fluoroscopy, and radiofrequency times (median ± standard deviation, range) were 123 ± 42 (50-250), 24 ± 13 (3-82), and 10 ± 8 (1.17-43.3) min, respectively. Three patients had vascular complications not requiring surgical intervention. There were no complications related to the remote catheter manipulation system.CONCLUSION: Cavo-tricuspid isthmus ablation for typical AFl can be safely and effectively performed with the AMIGO™. The learning curve seems to be short even for physicians with limited ablation experience.
Etiquetas de esta biblioteca: No hay etiquetas de esta biblioteca para este título. Ingresar para agregar etiquetas.
    valoración media: 0.0 (0 votos)
Tipo de ítem Ubicación actual Signatura Estado Fecha de vencimiento
Artículo Artículo PC8222 (Navegar estantería) Disponible

Formato Vancouver:
López-Gil M, Salgado R, Merino JL, Datino T, Figueroa J, Arenal A et al. Cavo-tricuspid isthmus radiofrequency ablation using a novel remote navigation catheter system in patients with typical atrial flutter. Europace. 2014 Apr;16(4):558-62.

PMID: 24058180

Contiene 18 referencias

AIMS: A new remote catheter system (AMIGO™ Remote Catheter System) compatible with conventional ablation catheters is now commercially available but no data about its performance in clinical use during ablation have been reported. This study evaluates the feasibility, efficacy, and safety of cavo-tricuspid isthmus (CTI) ablation with this system in patients with typical atrial flutter (AFl).METHODS AND RESULTS: Sixty patients with typical AFl underwent CTI ablation using the new remote catheter navigation system with 8 mm tip or irrigated catheters in three centres following each centre's routine practice. The endpoint was stable bidirectional CTI block. CTI ablation was successful in 98% of patients. Ablation was completed manually in one patient. The overall procedure, fluoroscopy, and radiofrequency times (median ± standard deviation, range) were 123 ± 42 (50-250), 24 ± 13 (3-82), and 10 ± 8 (1.17-43.3) min, respectively. Three patients had vascular complications not requiring surgical intervention. There were no complications related to the remote catheter manipulation system.CONCLUSION: Cavo-tricuspid isthmus ablation for typical AFl can be safely and effectively performed with the AMIGO™. The learning curve seems to be short even for physicians with limited ablation experience.

No hay comentarios para este ejemplar.

Ingresar a su cuenta para colocar un comentario.

Con tecnología Koha