Rapid diagnosis of invasive pneumococcal disease in pediatric population. (Registro nro. 4807)

000 -CABECERA
Campo de control de longitud fija na a22 4500
003 - IDENTIFICADOR DEL NÚMERO DE CONTROL
Campo de control PC4807
005 - FECHA Y HORA DE LA ÚLTIMA TRANSACCIÓN
Campo de control 20200129130046.0
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA
Campo de control de longitud fija 130622s2013 xxx||||| |||| 00| 0 eng d
040 ## - FUENTE DE LA CATALOGACIÓN
Centro transcriptor H12O
041 ## - CÓDIGO DE LENGUA
Código de lengua del texto/banda sonora o título independiente eng
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
Nombre de persona Ruiz Contreras, Jesús
9 (RLIN) 811
Término indicativo de función Pediatría
245 00 - MENCIÓN DE TÍTULO
Título Rapid diagnosis of invasive pneumococcal disease in pediatric population.
Tipo de material [artículo]
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Nombre del editor distribuidor etc. Journal of microbiological methods,
Fecha de publicación distribución etc. 2013
300 ## - DESCRIPCIÓN FÍSICA
Extensión 93(2):116-20.
500 ## - NOTA GENERAL
Nota general Formato Vancouver:
Picazo JJ, Contreras JR, Ríos E, Culebras E, Rodríguez-Avial I, Méndez C et al. Heracles Study Group. Rapid diagnosis of invasive pneumococcal disease in pediatric population. J Microbiol Methods. 2013 May;93(2):116-20.
501 ## - NOTA DE “CON”
Nota de "Con" PMID: 23499921
504 ## - NOTA DE BIBLIOGRAFÍA; ETC.
Nota de bibliografía etc. Contiene 20 referencias
520 ## - NOTA DE SUMARIO; ETC.
Sumario etc. The aim of this study was to evaluate the Binax NOW immunochromatographic pneumococcal antigen test for the identification of Streptococcus pneumoniae in pleural and cerebrospinal fluids from children with suspected invasive pneumococcal disease. The results were compared with those obtained by PCR. Binax NOW was applied to these samples as recommended by the manufacturer for urine and cerebrospinal samples. Detection of pneumococcal DNA was performed by real-time PCR assay targeting the autolysin gene (lytA). Of the 199 samples analyzed, 131 were positive by both Binax NOW and lytA PCR, and 36 samples were negative by both techniques. Using the real-time PCR as a comparative method to the Binax for the detection of S. pneumoniae, the sensitivity and specificity of Binax NOW was 88% and 72.5%, respectively. Of the 145 positive samples analyzed by Binax NOW, 119 showed intense coloring of the sample line and 26 showed weak intensity. Conventional culture is the most common method in clinical settings, but Binax NOW is an easier and faster test for identifying S. pneumoniae in pleural and cerebrospinal fluids from children with suspected invasive pneumococcal disease.
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD
9 (RLIN) 446
Nombre de entidad o nombre de jurisdicción como elemento inicial Servicio de Pediatría-Neonatología
856 ## - LOCALIZACIÓN Y ACCESO ELECTRÓNICOS
Identificador Uniforme del Recurso (URI) http://pc-h12o-es.m-hdoct.a17.csinet.es/pdf/pc/4/pc4807.pdf
Acceso Solicitar documento
942 ## - ENTRADA PARA ELEMENTOS AGREGADOS (KOHA)
Suprimido en OPAC Público
Fuente de clasificación o esquema de ordenación en estanterías
Koha [por defecto] tipo de item Artículo
Existencias
Suprimido Estado de pérdida Fuente de clasificación o esquema de ordenación en estanterías Estropeado No para préstamo Localización permanente Localización actual Fecha de adquisición Signatura completa Fecha última consulta Fecha del precio de reemplazo Tipo de item de Koha
          Hospital Universitario 12 de Octubre Hospital Universitario 12 de Octubre 2020-01-29 PC4807 2020-01-29 2020-01-29 Artículo

Con tecnología Koha