Biblioteca Hospital 12 de Octubre
Vista normal Vista MARC Vista ISBD

Rapid diagnosis of invasive pneumococcal disease in pediatric population. [artículo]

Por: Ruiz Contreras, Jesús [Pediatría].
Colaborador(es): Servicio de Pediatría-Neonatología.
Editor: Journal of microbiological methods, 2013Descripción: 93(2):116-20.Recursos en línea: Solicitar documento Resumen: The aim of this study was to evaluate the Binax NOW immunochromatographic pneumococcal antigen test for the identification of Streptococcus pneumoniae in pleural and cerebrospinal fluids from children with suspected invasive pneumococcal disease. The results were compared with those obtained by PCR. Binax NOW was applied to these samples as recommended by the manufacturer for urine and cerebrospinal samples. Detection of pneumococcal DNA was performed by real-time PCR assay targeting the autolysin gene (lytA). Of the 199 samples analyzed, 131 were positive by both Binax NOW and lytA PCR, and 36 samples were negative by both techniques. Using the real-time PCR as a comparative method to the Binax for the detection of S. pneumoniae, the sensitivity and specificity of Binax NOW was 88% and 72.5%, respectively. Of the 145 positive samples analyzed by Binax NOW, 119 showed intense coloring of the sample line and 26 showed weak intensity. Conventional culture is the most common method in clinical settings, but Binax NOW is an easier and faster test for identifying S. pneumoniae in pleural and cerebrospinal fluids from children with suspected invasive pneumococcal disease.
Etiquetas de esta biblioteca: No hay etiquetas de esta biblioteca para este título. Ingresar para agregar etiquetas.
    valoración media: 0.0 (0 votos)
Tipo de ítem Ubicación actual Signatura Estado Fecha de vencimiento
Artículo Artículo PC4807 (Navegar estantería) Disponible

Formato Vancouver:
Picazo JJ, Contreras JR, Ríos E, Culebras E, Rodríguez-Avial I, Méndez C et al. Heracles Study Group. Rapid diagnosis of invasive pneumococcal disease in pediatric population. J Microbiol Methods. 2013 May;93(2):116-20.

PMID: 23499921

Contiene 20 referencias

The aim of this study was to evaluate the Binax NOW immunochromatographic pneumococcal antigen test for the identification of Streptococcus pneumoniae in pleural and cerebrospinal fluids from children with suspected invasive pneumococcal disease. The results were compared with those obtained by PCR. Binax NOW was applied to these samples as recommended by the manufacturer for urine and cerebrospinal samples. Detection of pneumococcal DNA was performed by real-time PCR assay targeting the autolysin gene (lytA). Of the 199 samples analyzed, 131 were positive by both Binax NOW and lytA PCR, and 36 samples were negative by both techniques. Using the real-time PCR as a comparative method to the Binax for the detection of S. pneumoniae, the sensitivity and specificity of Binax NOW was 88% and 72.5%, respectively. Of the 145 positive samples analyzed by Binax NOW, 119 showed intense coloring of the sample line and 26 showed weak intensity. Conventional culture is the most common method in clinical settings, but Binax NOW is an easier and faster test for identifying S. pneumoniae in pleural and cerebrospinal fluids from children with suspected invasive pneumococcal disease.

No hay comentarios para este ejemplar.

Ingresar a su cuenta para colocar un comentario.

Con tecnología Koha