Radiation dose and image quality for paediatric interventional cardiology systems. A national survey in Chile [artículo]

Por: Martínez Gómez, Luis Carlos [Radiofísica Hospitalaria].
Colaborador(es): Servicio de Radiofísica Hospitalaria.
Editor: Radiation Protection Dosimetry, 2011Descripción: 147(3):429-438.Recursos en línea: Solicitar documento Resumen: Radiation dose and image quality for paediatric protocols in all five X-ray fluoroscopy systems used for interventional cardiology procedures existing in Chile have been evaluated. Entrance surface air kerma (ESAK) and image quality using a test object (TO) and polymethyl methacrylate (PMMA) phantoms have been measured for the typical paediatric patient thicknesses (4-16 cm of PMMA). Images from fluoroscopy (low (FL), medium and high) and cine (CI) modes have been archived in DICOM format. Signal-to-noise ratio (SNR), figure of merit (FOM) and high-contrast spatial resolution (HCSR) have been computed from the images. The ratio between the maximum and the minimum value of ESAK per frame for a given fluoroscopy mode between the five systems ranges from 2 to 5 and from 14 to 38 for CI mode. SNR, FOM and HCSR showed a great variability for the different acquisition modes (AMs) and PMMA thickness. In the near future, it is urgent to upgrade Chilean legislation on radiation protection to incorporate quality assurance programmes that will allow us to evaluate and optimise the X-ray systems used in medical applications. Increments in doses per frame when increasing phantom thickness and when used CI runs instead of FL runs can be considered by the cardiologist in the good management of patient dose and allow them to select the best imaging AM during clinical procedures.
Etiquetas de esta biblioteca: No hay etiquetas de esta biblioteca para este título. Ingresar para agregar etiquetas.
    valoración media: 0.0 (0 votos)
Tipo de ítem Ubicación actual Signatura Estado Fecha de vencimiento
Artículo Artículo PC7388 (Navegar estantería) Disponible

Formato Vancouver:
Ubeda C, Vano E, Miranda P, Leyton F, Martinez LC, Oyarzun C. Radiation dose and image quality for paediatric interventional cardiology systems. A national survey in Chile. Radiat Prot Dosimetry. 2011;147(3):429-38.

PMID: 21148589

Contiene 31 referencias

Radiation dose and image quality for paediatric protocols in all five X-ray fluoroscopy systems used for interventional cardiology procedures existing in Chile have been evaluated. Entrance surface air kerma (ESAK) and image quality using a test object (TO) and polymethyl methacrylate (PMMA) phantoms have been measured for the typical paediatric patient thicknesses (4-16 cm of PMMA). Images from fluoroscopy (low (FL), medium and high) and cine (CI) modes have been archived in DICOM format. Signal-to-noise ratio (SNR), figure of merit (FOM) and high-contrast spatial resolution (HCSR) have been computed from the images. The ratio between the maximum and the minimum value of ESAK per frame for a given fluoroscopy mode between the five systems ranges from 2 to 5 and from 14 to 38 for CI mode. SNR, FOM and HCSR showed a great variability for the different acquisition modes (AMs) and PMMA thickness. In the near future, it is urgent to upgrade Chilean legislation on radiation protection to incorporate quality assurance programmes that will allow us to evaluate and optimise the X-ray systems used in medical applications. Increments in doses per frame when increasing phantom thickness and when used CI runs instead of FL runs can be considered by the cardiologist in the good management of patient dose and allow them to select the best imaging AM during clinical procedures.