Resumen: Introduction and objectives: This report presents the findings of the 2014 Spanish Catheter Ablation Registry. Methods: For data collection, each center was allowed to choose freely between 2 systems: retrospective, requiring the completion of a standardized questionnaire, and prospective, involving reporting to a central database. Results: Data were collected from 85 centers. A total of 12 871 ablation procedures were performed, for a mean of 149.5±103 procedures per center. The ablation targets most frequently treated were atrioventricular nodal reentrant tachycardia (n=3026; 23.5%), cavotricuspid isthmus (n=2833; 22.0%), and atrial fibrillation (n=2498; 19.4%). The number of ablation procedures for ventricular arrhythmias was similar to that of 2013, but there was a slight increase in the treatment of all the ventricular substrates, especially those associated with idiopathic ventricular tachycardia and scarring following myocardial infarction. The overall success rate was 95%, the rate of major complications was 1.3%, and the mortality rate was 0.02%. Conclusions: The 2014 registry shows that the number of ablation procedures performed continued its upward trend and that, overall, the success rate was high and the number of complications low. Ablation of complex conditions continued to increase.
Etiquetas de esta biblioteca: No hay etiquetas de esta biblioteca para este título. Ingresar para agregar etiquetas.
    valoración media: 0.0 (0 votos)
Tipo de ítem Ubicación actual Signatura Estado Fecha de vencimiento
Artículo Artículo PC17375 (Navegar estantería) Disponible

Formato Vancouver:
Gil Ortega I, Pedrote Martínez A, Fontenla Cerezuela A; Spanish Catheter Ablation Registry collaborators. Spanish Catheter Ablation Registry. 14th Official Report of the Spanish Society of Cardiology Working Group on Electrophysiology and Arrhythmias (2014). Rev Esp Cardiol (Engl Ed). 2015 Dec;68(12):1127-37.

PMID: 26507960

Contiene 14 referencias

Erratum in: Rev Esp Cardiol (Engl Ed). 2016 Oct;69(10):1000.

Introduction and objectives: This report presents the findings of the 2014 Spanish Catheter Ablation Registry.
Methods: For data collection, each center was allowed to choose freely between 2 systems: retrospective, requiring the completion of a standardized questionnaire, and prospective, involving reporting to a central database.
Results: Data were collected from 85 centers. A total of 12 871 ablation procedures were performed, for a mean of 149.5±103 procedures per center. The ablation targets most frequently treated were atrioventricular nodal reentrant tachycardia (n=3026; 23.5%), cavotricuspid isthmus (n=2833; 22.0%), and atrial fibrillation (n=2498; 19.4%). The number of ablation procedures for ventricular arrhythmias was similar to that of 2013, but there was a slight increase in the treatment of all the ventricular substrates, especially those associated with idiopathic ventricular tachycardia and scarring following myocardial infarction. The overall success rate was 95%, the rate of major complications was 1.3%, and the mortality rate was 0.02%.
Conclusions: The 2014 registry shows that the number of ablation procedures performed continued its upward trend and that, overall, the success rate was high and the number of complications low. Ablation of complex conditions continued to increase.