Biblioteca Hospital 12 de Octubre
Vista normal Vista MARC Vista ISBD

Coronary artery perforation: don't rush, IVUS may be useful. [caso clínico]

Por: Jurado Román, Alfonso [Cardiología] | García Tejada, Julio [Cardiología] | Hernández Hernández, Felipe [Cardiología] | Granda Nistal, Carolina [Cardiología] | Velázquez Martín, María Teresa [Cardiología] | Albarrán González-Trevilla, Agustín [Cardiología] | Tascón Pérez, Juan Carlos [Cardiología].
Colaborador(es): Servicio de Cardiología.
Tipo de material: materialTypeLabelArtículoEditor: Revista portuguesa de cardiologia : orgão oficial da Sociedade Portuguesa de Cardiologia = Portuguese journal of cardiology : an official journal of the Portuguese Society of Cardiology, 2015Descripción: 34(10):623.e1-3.Recursos en línea: Solicitar documento Resumen: Coronary artery perforation (CAP) is a rare but potentially fatal complication of percutaneous coronary intervention. Polytetrafluoroethylene-covered stents prevent blood leakage between struts with a high rate of success. However, they lack elasticity and rapid and correct deployment is difficult. They have also a higher rate of stent restenosis and thrombosis. For these reasons, optimal deployment is essential. Although severe CAP needs an emergent solution, after stabilizing the patient, intracoronary imaging techniques may be useful to ensure correct expansion and reduce further adverse events. We present a case that shows the potential role of intravascular ultrasound in the resolution of a CAP.
Etiquetas de esta biblioteca: No hay etiquetas de esta biblioteca para este título. Ingresar para agregar etiquetas.
    valoración media: 0.0 (0 votos)

Formato Vancouver:
Jurado Román A, García Tejada J, Hernández Hernández F, Granda Nistal C, Velázquez Martín MT, González Trevilla AA et al. Coronary artery perforation: don't rush, IVUS may be useful. Rev Port Cardiol. 2015 Oct;34(10):623.e1-3.

PMID: 26437891

Contiene 3 referencias

Coronary artery perforation (CAP) is a rare but potentially fatal complication of percutaneous coronary intervention. Polytetrafluoroethylene-covered stents prevent blood leakage between struts with a high rate of success. However, they lack elasticity and rapid and correct deployment is difficult. They have also a higher rate of stent restenosis and thrombosis. For these reasons, optimal deployment is essential. Although severe CAP needs an emergent solution, after stabilizing the patient, intracoronary imaging techniques may be useful to ensure correct expansion and reduce further adverse events. We present a case that shows the potential role of intravascular ultrasound in the resolution of a CAP.

No hay comentarios para este ejemplar.

Ingresar a su cuenta para colocar un comentario.

Con tecnología Koha