Biblioteca Hospital 12 de Octubre
Vista normal Vista MARC Vista ISBD

Cardiac preload responsiveness in children with cardiovascular dysfunction or dilated cardiomyopathy: a multicenter observational study. [artículo]

Por: Sánchez Díaz, Juan Ignacio [Pediatría].
Colaborador(es): Servicio de Pediatría-Neonatología.
Tipo de material: materialTypeLabelArtículoEditor: Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies, 2015Descripción: 16(1):45-53.Recursos en línea: Solicitar documento Resumen: Objectives: To characterize cardiac preload responsiveness in pediatric patients with cardiovascular dysfunction and dilated cardiomyopathy using global end-diastolic volume index, stroke volume index, cardiac index, and extravascular lung water index. Design: Prospective multicenter observational study. Setting: Medical/surgical PICUs of seven Spanish University Medical Centers. Patients: Seventy-five pediatric patients (42 male, 33 female), median age 36 months (range, 1-207 mo), were divided into three groups: normal cardiovascular status, cardiovascular dysfunction, and dilated cardiomyopathy. Interventions: All patients received hemodynamic monitoring with PiCCO2 (Pulsion Medical System SE, Munich, Germany). We evaluated 598 transpulmonary thermodilution sets of measurements. In 40 patients, stroke volume index, cardiac index, and global end-diastolic volume index were measured before and after 66 fluid challenges and loadings to test fluid responsiveness at different preload levels. Measurements and main results: Global end-diastolic volume versus predicted body surface area exhibits a power-law relationship: Global end-diastolic volume = 488.8·predicted body surface area (r = 0.93). Four levels of cardiac preload were established from the resulting "normal" global end-diastolic volume index (= 488.8·predicted body surface area). Stroke volume index and cardiac index versus global end-diastolic volume index/normal global end-diastolic volume index built using a linear mixed model analysis emulated Frank-Starling curves: in cardiovascular dysfunction group, stroke volume index (geometric mean [95% CI]) was 27 mL/m (24-31 mL/m) at "≤ 0.67 times normal global end-diastolic volume index," 37 mL/m (35-40 mL/m) at "> 0.67 ≤ 1.33 times normal global end-diastolic volume index" (Δ stroke volume index = 35%; p < 0.0001; area under the receiver-operating characteristic curve = 75%), 45 mL/ m (41-49 mL/m) at "> 1.33 ≤ 1.51 times normal global end-diastolic volume index" (Δ stroke volume index = 21%; p < 0.0001; area under the receiver-operating characteristic curve = 73%), and 47 mL/m (43-51 mL/m) at "> 1.51 times normal global end-diastolic volume index" (Δ stroke volume index = 4%; p = 1; area under the receiver-operating characteristic curve = 54%). In dilated cardiomyopathy group, stroke volume index was 21 mL/m (17-26 mL/m) at "> 0.67 ≤ 1.33 times normal global end-diastolic volume index," 27 mL/m (21-34 mL/ m) at "> 1.33 ≤ 1.51 times normal global end-diastolic volume index" (Δ stroke volume index = 29%; p = 0.005; area under the receiver-operating characteristic curve = 64%), and 25 mL/m (20-32 mL/m) at "> 1.51 times normal global end-diastolic volume index" (Δ stroke volume index = -8%; p = 1; area under the receiver-operating characteristic curve = 54%). Conclusions: This study provides "normal" values for global end-diastolic volume index and limits of cardiac preload responsiveness in pediatric patients with cardiovascular dysfunction and dilated cardiomyopathy: 1.33 times normal global end-diastolic volume index represents the upper limit of patent cardiac preload responsiveness, with the highest expected responsiveness being below 0.67 times normal global end-diastolic volume index. The maximum response of the Frank-Starling relationship and therefore the level of no additional preload reserve is 1.33 to 1.51 times normal global end-diastolic volume index. Above 1.51 times normal global end-diastolic volume index preload responsiveness is unlikely, and the risk of pulmonary edema is maximal.
Etiquetas de esta biblioteca: No hay etiquetas de esta biblioteca para este título. Ingresar para agregar etiquetas.
    valoración media: 0.0 (0 votos)
Tipo de ítem Ubicación actual Signatura Estado Fecha de vencimiento
Artículo Artículo PC16834 (Navegar estantería) Disponible

Formato Vancouver:
De la Oliva P, Menéndez Suso JJ, Iglesias Bouzas M, Álvarez Rojas E, González Gómez JM, Roselló P et al; Spanish Group for Preload Responsiveness Assessment in Children. Cardiac preload responsiveness in children with cardiovascular dysfunction or dilated cardiomyopathy: a multicenter observational study. Pediatr Crit Care Med. 2015 Jan;16(1):45-53.

PMID: 25360857

Contiene 40 referencias

Objectives: To characterize cardiac preload responsiveness in pediatric patients with cardiovascular dysfunction and dilated cardiomyopathy using global end-diastolic volume index, stroke volume index, cardiac index, and extravascular lung water index.
Design: Prospective multicenter observational study.
Setting: Medical/surgical PICUs of seven Spanish University Medical Centers.
Patients: Seventy-five pediatric patients (42 male, 33 female), median age 36 months (range, 1-207 mo), were divided into three groups: normal cardiovascular status, cardiovascular dysfunction, and dilated cardiomyopathy.
Interventions: All patients received hemodynamic monitoring with PiCCO2 (Pulsion Medical System SE, Munich, Germany). We evaluated 598 transpulmonary thermodilution sets of measurements. In 40 patients, stroke volume index, cardiac index, and global end-diastolic volume index were measured before and after 66 fluid challenges and loadings to test fluid responsiveness at different preload levels.

Measurements and main results: Global end-diastolic volume versus predicted body surface area exhibits a power-law relationship: Global end-diastolic volume = 488.8·predicted body surface area (r = 0.93). Four levels of cardiac preload were established from the resulting "normal" global end-diastolic volume index (= 488.8·predicted body surface area). Stroke volume index and cardiac index versus global end-diastolic volume index/normal global end-diastolic volume index built using a linear mixed model analysis emulated Frank-Starling curves: in cardiovascular dysfunction group, stroke volume index (geometric mean [95% CI]) was 27 mL/m (24-31 mL/m) at "≤ 0.67 times normal global end-diastolic volume index," 37 mL/m (35-40 mL/m) at "> 0.67 ≤ 1.33 times normal global end-diastolic volume index" (Δ stroke volume index = 35%; p < 0.0001; area under the receiver-operating characteristic curve = 75%), 45 mL/ m (41-49 mL/m) at "> 1.33 ≤ 1.51 times normal global end-diastolic volume index" (Δ stroke volume index = 21%; p < 0.0001; area under the receiver-operating characteristic curve = 73%), and 47 mL/m (43-51 mL/m) at "> 1.51 times normal global end-diastolic volume index" (Δ stroke volume index = 4%; p = 1; area under the receiver-operating characteristic curve = 54%). In dilated cardiomyopathy group, stroke volume index was 21 mL/m (17-26 mL/m) at "> 0.67 ≤ 1.33 times normal global end-diastolic volume index," 27 mL/m (21-34 mL/ m) at "> 1.33 ≤ 1.51 times normal global end-diastolic volume index" (Δ stroke volume index = 29%; p = 0.005; area under the receiver-operating characteristic curve = 64%), and 25 mL/m (20-32 mL/m) at "> 1.51 times normal global end-diastolic volume index" (Δ stroke volume index = -8%; p = 1; area under the receiver-operating characteristic curve = 54%).
Conclusions: This study provides "normal" values for global end-diastolic volume index and limits of cardiac preload responsiveness in pediatric patients with cardiovascular dysfunction and dilated cardiomyopathy: 1.33 times normal global end-diastolic volume index represents the upper limit of patent cardiac preload responsiveness, with the highest expected responsiveness being below 0.67 times normal global end-diastolic volume index. The maximum response of the Frank-Starling relationship and therefore the level of no additional preload reserve is 1.33 to 1.51 times normal global end-diastolic volume index. Above 1.51 times normal global end-diastolic volume index preload responsiveness is unlikely, and the risk of pulmonary edema is maximal.

No hay comentarios para este ejemplar.

Ingresar a su cuenta para colocar un comentario.

Con tecnología Koha