Type of homogenization and fat loss during continuous infusion of human milk. [artículo]

Por: García Lara, Nadia Raquel [Neonatología] | Escuder Vieco, Diana [Neonatología] | Alonso Díaz, Clara [Neonatología] | Vázquez Román, Sara [Neonatología] | Cruz Bértolo, Javier de la [Epidemiología Clínica] | Pallás Alonso, Carmen Rosa [Neonatología].
Colaborador(es): Servicio de Pediatría-Neonatología | Instituto de Investigación imas12.
Tipo de material: materialTypeLabelArtículoEditor: Journal of human lactation : official journal of International Lactation Consultant Association, 2014Descripción: 30(4):436-41.Recursos en línea: Solicitar documento Resumen: Background: Substantial fat loss may occur during continuous feeding of human milk (HM). A decrease of fat loss has been described following homogenization. Well-established methods of homogenization of HM for routine use in the neonatal intensive care unit (NICU) would be desirable. Objective: We compared the loss of fat based on the use of 3 different methods for homogenizing thawed HM during continuous feeding. Methods: Sixteen frozen donor HM samples were thawed, homogenized with ultrasound and separated into 3 aliquots ("baseline agitation," "hourly agitation," and "ultrasound"), and then frozen for 48 hours. Aliquots were thawed again and a baseline agitation was applied. Subsequently, aliquots baseline agitation and hourly agitation were drawn into a syringe, while ultrasound was applied to aliquot ultrasound before it was drawn into a syringe. The syringes were loaded into a pump (2 mL/h; 4 hours). At hourly intervals the hourly agitation infusion was stopped, the syringe was disconnected and gently shaken. During infusion, samples from the 3 groups were collected hourly for analysis of fat and caloric content. Results: The 3 groups of homogenization showed similar fat content at the beginning of the infusion. For fat, mean (SD) hourly changes of -0.03 (0.01), -0.09 (0.01), and -0.09 (0.01) g/dL were observed for the hourly agitation, baseline agitation, and ultrasound groups, respectively. The decrease was smaller for the hourly agitation group (P < .001). Conclusion: When thawed HM is continuously infused, a smaller fat loss is observed when syringes are agitated hourly versus when ultrasound or a baseline homogenization is used.
Etiquetas de esta biblioteca: No hay etiquetas de esta biblioteca para este título. Ingresar para agregar etiquetas.
    valoración media: 0.0 (0 votos)
Tipo de ítem Ubicación actual Signatura Estado Fecha de vencimiento
Artículo Artículo PC16680 (Navegar estantería) Disponible

Formato Vancouver:
García Lara NR, Escuder Vieco D, Alonso Díaz C, Vázquez Román S, De la Cruz Bértolo J, Pallás Alonso CR. Type of homogenization and fat loss during continuous infusion of human milk. J Hum Lact. 2014 Nov;30(4):436-41.

PMID: 25122692

Contiene 23 referencias

Background: Substantial fat loss may occur during continuous feeding of human milk (HM). A decrease of fat loss has been described following homogenization. Well-established methods of homogenization of HM for routine use in the neonatal intensive care unit (NICU) would be desirable.

Objective: We compared the loss of fat based on the use of 3 different methods for homogenizing thawed HM during continuous feeding.
Methods: Sixteen frozen donor HM samples were thawed, homogenized with ultrasound and separated into 3 aliquots ("baseline agitation," "hourly agitation," and "ultrasound"), and then frozen for 48 hours. Aliquots were thawed again and a baseline agitation was applied. Subsequently, aliquots baseline agitation and hourly agitation were drawn into a syringe, while ultrasound was applied to aliquot ultrasound before it was drawn into a syringe. The syringes were loaded into a pump (2 mL/h; 4 hours). At hourly intervals the hourly agitation infusion was stopped, the syringe was disconnected and gently shaken. During infusion, samples from the 3 groups were collected hourly for analysis of fat and caloric content.
Results: The 3 groups of homogenization showed similar fat content at the beginning of the infusion. For fat, mean (SD) hourly changes of -0.03 (0.01), -0.09 (0.01), and -0.09 (0.01) g/dL were observed for the hourly agitation, baseline agitation, and ultrasound groups, respectively. The decrease was smaller for the hourly agitation group (P < .001).
Conclusion: When thawed HM is continuously infused, a smaller fat loss is observed when syringes are agitated hourly versus when ultrasound or a baseline homogenization is used.