Biblioteca Hospital 12 de Octubre
Vista normal Vista MARC Vista ISBD

New gestational phase-specific cutoff values for the use of the soluble fms-like tyrosine kinase-1/placental growth factor ratio as a diagnostic test for preeclampsia. [artículo]

Por: Herráiz García, Ignacio [Obstetricia y Ginecología] | Galindo Izquierdo, Alberto [Obstetricia y Ginecología].
Colaborador(es): Servicio de Obstetricia y Ginecología.
Tipo de material: materialTypeLabelArtículoEditor: Hypertension (Dallas, Tex. : 1979), 2014Descripción: 63(2):346-52.Recursos en línea: Solicitar documento Resumen: To establish gestational phase adapted cutoffs for the use of the soluble fms-like tyrosine kinase-1 (sFlt-1)/placental growth factor (PlGF) ratio as a diagnostic tool for preeclampsia in the clinical setting, a multicenter case-control study including a total of 1149 patients was performed. We report normal values of sFlt-1, PlGF, and the sFlt-1/PlGF ratio based on the analysis of a total of 877 patients with uneventful pregnancy outcome. A total of 234 patients with preeclampsia and a matched cohort consisting of 468 patients with normal pregnancy outcome were compared, and sFlt-1 and PlGF were measured on an automated platform. Separate cutoffs for the sFlt-1/PlGF ratio were determined for the early (20+0-33+6 weeks) and the late gestational phase (34+0 weeks-delivery). For each of the 2 gestational phases, 2 independent cutoffs framing an equivocal zone were determined: the first cutoff with focus on high sensitivity, and the second focusing on high specificity. Between 20+0 and 33+6 weeks, the cutoffs at ≤33 and ≥85 resulted in a sensitivity/specificity of 95%/94% and 88%/99.5%, respectively. An sFlt-1/PlGF ratio of ≤33 had the lowest likelihood of a negative test (0.05; 95% confidence interval, 0.02-0.13), whereas values ≥85 had the highest likelihood of a positive test (176; 95% confidence interval, 24.88-1245). After 34+0 weeks, the cutoffs at ≤33 and ≥110 yielded a sensitivity/specificity of 89.6%/73.1% and 58.2%/95.5%, respectively. The approach to use multiple cutoffs for the early and late gestational phase enhances the diagnostic accuracy of the sFlt-1/PlGF ratio as a diagnostic tool for preeclampsia.
Etiquetas de esta biblioteca: No hay etiquetas de esta biblioteca para este título. Ingresar para agregar etiquetas.
    valoración media: 0.0 (0 votos)

Formato Vancouver:
Verlohren S, Herraiz I, Lapaire O, Schlembach D, Zeisler H, Calda P et al. New gestational phase-specific cutoff values for the use of the soluble fms-like tyrosine kinase-1/placental growth factor ratio as a diagnostic test for preeclampsia. Hypertension. 2014 Feb;63(2):346-52.

PMID: 24166751

Contiene 21 referencias

To establish gestational phase adapted cutoffs for the use of the soluble fms-like tyrosine kinase-1 (sFlt-1)/placental growth factor (PlGF) ratio as a diagnostic tool for preeclampsia in the clinical setting, a multicenter case-control study including a total of 1149 patients was performed. We report normal values of sFlt-1, PlGF, and the sFlt-1/PlGF ratio based on the analysis of a total of 877 patients with uneventful pregnancy outcome. A total of 234 patients with preeclampsia and a matched cohort consisting of 468 patients with normal pregnancy outcome were compared, and sFlt-1 and PlGF were measured on an automated platform. Separate cutoffs for the sFlt-1/PlGF ratio were determined for the early (20+0-33+6 weeks) and the late gestational phase (34+0 weeks-delivery). For each of the 2 gestational phases, 2 independent cutoffs framing an equivocal zone were determined: the first cutoff with focus on high sensitivity, and the second focusing on high specificity. Between 20+0 and 33+6 weeks, the cutoffs at ≤33 and ≥85 resulted in a sensitivity/specificity of 95%/94% and 88%/99.5%, respectively. An sFlt-1/PlGF ratio of ≤33 had the lowest likelihood of a negative test (0.05; 95% confidence interval, 0.02-0.13), whereas values ≥85 had the highest likelihood of a positive test (176; 95% confidence interval, 24.88-1245). After 34+0 weeks, the cutoffs at ≤33 and ≥110 yielded a sensitivity/specificity of 89.6%/73.1% and 58.2%/95.5%, respectively. The approach to use multiple cutoffs for the early and late gestational phase enhances the diagnostic accuracy of the sFlt-1/PlGF ratio as a diagnostic tool for preeclampsia.

No hay comentarios para este ejemplar.

Ingresar a su cuenta para colocar un comentario.

Con tecnología Koha