Biblioteca Hospital 12 de Octubre

Prediction of coarctation of the aorta in the second half of pregnancy (Registro nro. 7637)

000 -CABECERA
Campo de control de longitud fija 03275na a2200277 4500
003 - IDENTIFICADOR DEL NÚMERO DE CONTROL
Campo de control PC7637
005 - FECHA Y HORA DE LA ÚLTIMA TRANSACCIÓN
Campo de control 20200320104258.0
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA
Campo de control de longitud fija 130622s2013
040 ## - FUENTE DE LA CATALOGACIÓN
Centro transcriptor H12O
041 ## - CÓDIGO DE LENGUA
Código de lengua del texto/banda sonora o título independiente eng
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
Nombre de persona Gómez Montes, Enery
9 (RLIN) 893
Término indicativo de función Obstetricia y Ginecología
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
Nombre de persona Herráiz García, Ignacio
9 (RLIN) 894
Término indicativo de función Obstetricia y Ginecología
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
Nombre de persona Mendoza Soto, Alberto
9 (RLIN) 849
Término indicativo de función Pediatría
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 895
Nombre de persona Escribano Abad, David
Término indicativo de función Obstetricia y Ginecología
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
Nombre de persona Galindo Izquierdo, Alberto
9 (RLIN) 896
Término indicativo de función Obstetricia y Ginecología
245 00 - MENCIÓN DE TÍTULO
Título Prediction of coarctation of the aorta in the second half of pregnancy
Tipo de material [artículo]
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Nombre del editor distribuidor etc. Ultrasound in Obstetrics & Gynecology,
Fecha de publicación distribución etc. 2013.
300 ## - DESCRIPCIÓN FÍSICA
Extensión 41(3):298-305.
500 ## - NOTA GENERAL
Nota general Formato Vancouver:
Gómez Montes E, Herraiz I, Mendoza A, Escribano D, Galindo A. Prediction of coarctation of the aorta in the second half of pregnancy. Ultrasound Obstet Gynecol. 2013;41(3):298-305.
504 ## - NOTA DE BIBLIOGRAFÍA; ETC.
Nota de bibliografía etc. Contiene 28 referencias, 5 figuras y 3 tablas.
520 ## - NOTA DE SUMARIO; ETC.
Sumario etc. Resumen:
Objective To determine which combination of cardiac parameters provides the best prediction of postnatal coarctation of the aorta (CoAo) in fetuses with cardiac asymmetry. Methods We selected all cases of disproportion of the ventricles and great vessels prenatally diagnosed between 2003 and 2010 at the Hospital Universitario ‘12 de Octubre’, Madrid, Spain. Only appropriate-forgestational age liveborn fetuses with isolated cardiac asymmetry and with complete postnatal follow-up were included in the study. Eighty-five cases were retrieved and analyzed. Logistic regression analysis was used to select the best predictors of CoAo. Optimal cut-offs for these parameters were identified and the corresponding likelihood ratios used to calculate the post-test probability of CoAo in each fetus. Results CoAo was confirmed in 41/85 neonates (48%). The parameters selected by logistic regression and their cut-off values were: gestational age at diagnosis ≤28 weeks, Z-score of diameter of the ascending aorta≤−1.5, pulmonary valve/aortic valve diameters ratio ≥1.6 and Z-score of the aortic isthmus diameter in the three vessels and trachea view ≤−2. We divided the study group into two subgroups: Group A, in whom the diagnosis was made at ≤28 weeks’ gestation (80% CoAo (32/40)); and Group B, in whom the diagnosis was made at >28 weeks (20% CoAo (9/45)). The mean post-test probabilities of CoAo were higher in fetuses with CoAo than in normal fetuses in both subgroups (Group A, 82 vs 55%; P=0.002 and Group B, 51 vs 20%; P<0.001). In addition, a rate of growth of the aortic valve of ≤0.24 mm/week provided 80% sensitivity and 100% specificity for predicting CoAo in Group A. Conclusions We have derived a multiparametric scoring system, combining size-based cardiac parameters and gestational age at diagnosis, which may improve the accuracy of fetal echocardiography for the stratification of the risk of CoAo. The objectivity and simplicity of its components may allow its implementation in fetal cardiology units.
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD
9 (RLIN) 427
Nombre de entidad o nombre de jurisdicción como elemento inicial Servicio de Obstetricia y Ginecología
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD
9 (RLIN) 446
Nombre de entidad o nombre de jurisdicción como elemento inicial Servicio de Pediatría-Neonatología
856 ## - LOCALIZACIÓN Y ACCESO ELECTRÓNICOS
Identificador Uniforme del Recurso (URI) http://pc-h12o-es.m-hdoct.a17.csinet.es/pdf/pc7637.pdf
Acceso Solicitar documento
942 ## - ENTRADA PARA ELEMENTOS AGREGADOS (KOHA)
Fuente de clasificación o esquema de ordenación en estanterías
Koha [por defecto] tipo de item Artículo
Suprimido en OPAC Público
Existencias
Suprimido Estado de pérdida Fuente de clasificación o esquema de ordenación en estanterías Estropeado No para préstamo Localización permanente Localización actual Fecha de adquisición Signatura completa Fecha última consulta Fecha del precio de reemplazo Tipo de item de Koha
          Hospital Universitario 12 de Octubre Hospital Universitario 12 de Octubre 2014-08-01 PC7637 2014-08-01 2014-08-01 Artículo

Con tecnología Koha