Stents ureterales metálicos. Presente y futuro. (Registro nro. 18001)
[ vista simple ]
000 -CABECERA | |
---|---|
Campo de control de longitud fija | nab a22 7a 4500 |
003 - IDENTIFICADOR DEL NÚMERO DE CONTROL | |
Campo de control | PC18001 |
005 - FECHA Y HORA DE LA ÚLTIMA TRANSACCIÓN | |
Campo de control | 20250623123254.0 |
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA | |
Campo de control de longitud fija | 250617b xxu||||| |||| 00| 0 eng d |
040 ## - FUENTE DE LA CATALOGACIÓN | |
Centro transcriptor | H12O |
041 ## - CÓDIGO DE LENGUA | |
Código de lengua del texto/banda sonora o título independiente | spa |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 1933 |
Nombre de persona | Pamplona Casamayor, Manuel |
Término indicativo de función | Urología |
245 00 - MENCIÓN DE TÍTULO | |
Título | Stents ureterales metálicos. Presente y futuro. |
Tipo de material | [revisión] |
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT) | |
Nombre del editor distribuidor etc. | Archivos españoles de urología, |
Fecha de publicación distribución etc. | 2016 |
300 ## - DESCRIPCIÓN FÍSICA | |
Extensión | 69(8):583-94. |
500 ## - NOTA GENERAL | |
Nota general | Formato Vancouver: Morcillo E, Fernández I, Pamplona M, Sánchez Margallo FM, Soria F. Stents ureterales metálicos. Presente y futuro. Arch Esp Urol. 2016 Oct;69(8):583-94. |
501 ## - NOTA DE “CON” | |
Nota de "Con" | PMID: 27725334 |
504 ## - NOTA DE BIBLIOGRAFÍA; ETC. | |
Nota de bibliografía etc. | Contiene 58 referencias |
520 ## - NOTA DE SUMARIO; ETC. | |
Sumario etc. | The management of ureteral obstruction of malignant origin or complicated benign obstruction continues to be a challenge for the urological community. In this sense, the use of metallic stents could be considered a useful alternative to the conventional drainage techniques, because it accomplishes the resolution of obstruction in a single procedure, without external diversions and without the adverse effects of current diversions. Another important advantage they offer is that they do not need replacement as frequently as double J catheters or nephrostomy tubes require. From their first applications in the upper urinary tract until now the design of metallic stents has experienced a notable evolution. The main obstacle at the beginning was the use of stents intended for other organic territories, which caused a high rate of failures, since they did not take into consideration in their designs the hostile environment represented by urine for this type of devices, neither the existence of ureteral peristaltism. Thanks to subsequent metallic designs (Memokath, Uventa, Allium Medical URS-stent, Resonance), the current generation of ureteral metallic stents has improved the success rate in comparison to classical designs, accommodating to ureteral dynamics and improving the coating and alloys. Despite these advances, today, their application is limited to very selected patients due to the onset of undesirable effects still associated with theses stents, such as obstructive urothelial hyperplasia, encrustation or migration. The precise knowledge of the physiopathological mechanisms responsible for the cited adverse effects, together with the application of Bioengineering enabling the development of drug eluting metallic stents, biocoated stents, or new biodegradable metallic materials that mitigate or diminish their effects, may be the key to allow the development of the ideal metallic stent. |
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD | |
9 (RLIN) | 220 |
Nombre de entidad o nombre de jurisdicción como elemento inicial | Servicio de Urología |
856 ## - LOCALIZACIÓN Y ACCESO ELECTRÓNICOS | |
Identificador Uniforme del Recurso (URI) | http://pc-h12o-es.m-hdoct.a17.csinet.es/pdf/pc/1/pc18001.pdf |
Acceso | Solicitar documento |
942 ## - ENTRADA PARA ELEMENTOS AGREGADOS (KOHA) | |
Fuente de clasificación o esquema de ordenación en estanterías | |
Koha [por defecto] tipo de item | Revisión |
Suprimido en OPAC | Público |
Suprimido | Estado de pérdida | Fuente de clasificación o esquema de ordenación en estanterías | Estropeado | No para préstamo | Localización permanente | Localización actual | Fecha de adquisición | Signatura completa | Fecha última consulta | Fecha del precio de reemplazo | Tipo de item de Koha |
---|---|---|---|---|---|---|---|---|---|---|---|
Hospital Universitario 12 de Octubre | Hospital Universitario 12 de Octubre | 2025-06-17 | PC18001 | 2025-06-17 | 2025-06-17 | Revisión |