Etiology and Programming Effects on Shock Efficacy in ICD Recipients. (Registro nro. 17803)
[ vista simple ]
000 -CABECERA | |
---|---|
Campo de control de longitud fija | nab a22 7a 4500 |
003 - IDENTIFICADOR DEL NÚMERO DE CONTROL | |
Campo de control | PC17803 |
005 - FECHA Y HORA DE LA ÚLTIMA TRANSACCIÓN | |
Campo de control | 20240326095840.0 |
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA | |
Campo de control de longitud fija | 240326b xxu||||| |||| 00| 0 eng d |
040 ## - FUENTE DE LA CATALOGACIÓN | |
Centro transcriptor | H12O |
041 ## - CÓDIGO DE LENGUA | |
Código de lengua del texto/banda sonora o título independiente | eng |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 2225 |
Nombre de persona | Fontenla Cerezuela, Adolfo |
Término indicativo de función | Cardiología |
245 00 - MENCIÓN DE TÍTULO | |
Título | Etiology and Programming Effects on Shock Efficacy in ICD Recipients. |
Tipo de material | [artículo] |
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT) | |
Nombre del editor distribuidor etc. | Pacing and clinical electrophysiology: PACE, |
Fecha de publicación distribución etc. | 2016 |
300 ## - DESCRIPCIÓN FÍSICA | |
Extensión | 39(1):73-80. |
500 ## - NOTA GENERAL | |
Nota general | Formato Vancouver: Bertomeu González V, Moreno Arribas J, Castillo Castillo J, Martínez Ferrer J, Viñolas X, Rodríguez A et al. Etiology and Programming Effects on Shock Efficacy in ICD Recipients. Pacing Clin Electrophysiol. 2016 Jan;39(1):73-80. |
501 ## - NOTA DE “CON” | |
Nota de "Con" | PMID: 26450114 |
504 ## - NOTA DE BIBLIOGRAFÍA; ETC. | |
Nota de bibliografía etc. | Contiene 20 referencias |
520 ## - NOTA DE SUMARIO; ETC. | |
Sumario etc. | Background: We sought to assess the efficacy of high-energy shocks to restore rhythm and predictors of success in patients with sustained ventricular arrhythmias and implantable cardioverter defibrillator (ICD). Methods and results: Data from 162 patients included in the UMBRELLA study that experienced one or more episodes of ventricular tachycardia (VT) for which ICD shocks of at least 30 Joules were delivered (appropriate high-energy shocks) were analyzed. In total, 456 ventricular arrhythmia episodes were registered. Forty four episodes (9.6%) from 39 patients (24%) had at least one ineffective high-energy shock delivered. Hypertrophic cardiomyopathy was more frequent among patients with unsuccessful shocks (10.3% vs 2.4%). Patients with ineffective shocks had higher proportion of sustained monomorphic ventricular arrhythmias (86.4%; the other 13.6% were sustained polymorphic and ventricular fibrillation [VF]) compared with patients with all their shocks effective (62.9%, P = 0.02). No statistical differences were found between groups in time from detection to the high-energy shock delivery, in tachycardia cycle length, or in antitachycardia pacing, but patients with ineffective high-energy shocks had higher proportion of previously ineffective low-energy shock (9.1% vs 0.5%, P = 0.01). Conclusion: We found a substantial rate of ineffective high-energy shocks for the treatment of VT or VF in patients with ICD. High-energy shock efficacy seems to be reduced by hypertrophic cardiomyopathy and by the administration of previous low-energy shocks. |
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD | |
9 (RLIN) | 119 |
Nombre de entidad o nombre de jurisdicción como elemento inicial | Servicio de Cardiología |
856 ## - LOCALIZACIÓN Y ACCESO ELECTRÓNICOS | |
Identificador Uniforme del Recurso (URI) | http://pc-h12o-es.m-hdoct.a17.csinet.es/pdf/pc/1/pc17803.pdf |
Acceso | Solicitar documento |
942 ## - ENTRADA PARA ELEMENTOS AGREGADOS (KOHA) | |
Fuente de clasificación o esquema de ordenación en estanterías | |
Koha [por defecto] tipo de item | Artículo |
Suprimido en OPAC | Público |
Suprimido | Estado de pérdida | Fuente de clasificación o esquema de ordenación en estanterías | Estropeado | No para préstamo | Localización permanente | Localización actual | Fecha de adquisición | Signatura completa | Fecha última consulta | Fecha del precio de reemplazo | Tipo de item de Koha |
---|---|---|---|---|---|---|---|---|---|---|---|
Hospital Universitario 12 de Octubre | Hospital Universitario 12 de Octubre | 2024-03-26 | PC17803 | 2024-03-26 | 2024-03-26 | Artículo |