Smart pumps and random safety audits in a Neonatal Intensive Care Unit: a new challenge for patient safety. (Registro nro. 17371)
[ vista simple ]
000 -CABECERA | |
---|---|
Campo de control de longitud fija | nab a22 7a 4500 |
003 - IDENTIFICADOR DEL NÚMERO DE CONTROL | |
Campo de control | PC17371 |
005 - FECHA Y HORA DE LA ÚLTIMA TRANSACCIÓN | |
Campo de control | 20230411132902.0 |
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA | |
Campo de control de longitud fija | 230411b xxu||||| |||| 00| 0 eng d |
040 ## - FUENTE DE LA CATALOGACIÓN | |
Centro transcriptor | H12O |
041 ## - CÓDIGO DE LENGUA | |
Código de lengua del texto/banda sonora o título independiente | eng |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 1851 |
Nombre de persona | Bergón Sendín, Elena |
Término indicativo de función | Neonatología |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 814 |
Nombre de persona | Pérez Grande, María del Carmen |
Término indicativo de función | Pediatría |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 821 |
Nombre de persona | Lora Pablos, David |
Término indicativo de función | Instituto Investigación I+12 |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 1848 |
Nombre de persona | Moral Pumarega, María Teresa |
Término indicativo de función | Neonatología |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 1854 |
Nombre de persona | Melgar Bonis, Ana |
Término indicativo de función | Neonatología |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 3243 |
Nombre de persona | Peña Peloche, Carmen |
Término indicativo de función | Neonatología |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 3244 |
Nombre de persona | Diezma Rodino, Mercedes |
Término indicativo de función | Neonatología |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 2979 |
Nombre de persona | García San José, Lidia |
Término indicativo de función | Neonatología |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 2925 |
Nombre de persona | Cabañes Alonso, Esther |
Término indicativo de función | Neonatología |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 1008 |
Nombre de persona | Pallás Alonso, Carmen Rosa |
Término indicativo de función | Neonatología |
245 00 - MENCIÓN DE TÍTULO | |
Título | Smart pumps and random safety audits in a Neonatal Intensive Care Unit: a new challenge for patient safety. |
Tipo de material | [artículo] |
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT) | |
Nombre del editor distribuidor etc. | BMC pediatrics, |
Fecha de publicación distribución etc. | 2015 |
300 ## - DESCRIPCIÓN FÍSICA | |
Extensión | 15:206. |
500 ## - NOTA GENERAL | |
Nota general | Formato Vancouver: Bergón Sendín E, Pérez Grande C, Lora Pablos D, Moral Pumarega MT, Melgar Bonis A, Peña Peloche C et al. Smart pumps and random safety audits in a Neonatal Intensive Care Unit: a new challenge for patient safety. BMC Pediatr. 2015 Dec 11;15:206. |
501 ## - NOTA DE “CON” | |
Nota de "Con" | PMID: 26654316 PMC4676130 |
504 ## - NOTA DE BIBLIOGRAFÍA; ETC. | |
Nota de bibliografía etc. | Contiene 23 referencias |
520 ## - NOTA DE SUMARIO; ETC. | |
Sumario etc. | Background: Random safety audits (RSA) are a safety tool enabling prevention of adverse events, but they have not been widely used in hospitals. The aim of this study was to use RSAs to assess and compare the frequency of appropriate use of infusion pump safety systems in a Neonatal Intensive Care Unit (NICU) before and after quality improvement interventions and to analyse the intravenous medication programming data. Methods: Prospective, observational study comparing the frequency of appropriate use of Alaris® CC smart pumps through RSAs over two periods, from 1 January to 31 December 2012 and from 1 November 2014 to 31 January 2015. Appropriate use was defined as all evaluated variables being correctly programmed into the same device. Between the two periods they were established interventions to improve the use of pumps. The information recorded at the pumps with the new security system, also extracted for one year. Results: Fifty-two measurements were collected during the first period and 160 measurements during the second period. The frequency of appropriate use was 73.13 % (117/160) in the second period versus 0 % (0/52) in the first period (p < 0.0001). Information was recorded on 44,924 infusions; in 46.03 % (20,680/44,924) of cases the drug name was recorded. In 2.5 % (532/20,680) of cases there was an attempt to exceed the absolute limit. Conclusions: Random Safety Audits were a very useful tool for detecting inappropriate use of pumps in the NICU. The improvement strategies were effective for improving appropriate use and programming of the intravenous medication infusion pumps in our NICU. |
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD | |
9 (RLIN) | 793 |
Nombre de entidad o nombre de jurisdicción como elemento inicial | Servicio de Neonatología |
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD | |
9 (RLIN) | 625 |
Nombre de entidad o nombre de jurisdicción como elemento inicial | Instituto de Investigación imas12 |
856 ## - LOCALIZACIÓN Y ACCESO ELECTRÓNICOS | |
Identificador Uniforme del Recurso (URI) | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4676130/ |
Acceso | Acceso libre |
942 ## - ENTRADA PARA ELEMENTOS AGREGADOS (KOHA) | |
Fuente de clasificación o esquema de ordenación en estanterías | |
Koha [por defecto] tipo de item | Artículo |
Suprimido en OPAC | Público |
Suprimido | Estado de pérdida | Fuente de clasificación o esquema de ordenación en estanterías | Estropeado | No para préstamo | Localización permanente | Localización actual | Fecha de adquisición | Signatura completa | Fecha última consulta | Fecha del precio de reemplazo | Tipo de item de Koha |
---|---|---|---|---|---|---|---|---|---|---|---|
Hospital Universitario 12 de Octubre | Hospital Universitario 12 de Octubre | 2023-04-11 | PC17371 | 2023-04-11 | 2023-04-11 | Artículo |