Biblioteca Hospital 12 de Octubre

Maternal serum sFlt-1/PlGF ratio in twin pregnancies with and without pre-eclampsia in comparison with singleton pregnancies. (Registro nro. 17147)

000 -CABECERA
Campo de control de longitud fija nab a22 7a 4500
003 - IDENTIFICADOR DEL NÚMERO DE CONTROL
Campo de control PC17147
005 - FECHA Y HORA DE LA ÚLTIMA TRANSACCIÓN
Campo de control 20230124120919.0
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA
Campo de control de longitud fija 230124b xxu||||| |||| 00| 0 eng d
040 ## - FUENTE DE LA CATALOGACIÓN
Centro transcriptor H12O
041 ## - CÓDIGO DE LENGUA
Código de lengua del texto/banda sonora o título independiente eng
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 896
Nombre de persona Galindo Izquierdo, Alberto
Término indicativo de función Obstetricia y Ginecología
245 00 - MENCIÓN DE TÍTULO
Título Maternal serum sFlt-1/PlGF ratio in twin pregnancies with and without pre-eclampsia in comparison with singleton pregnancies.
Tipo de material [artículo]
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Nombre del editor distribuidor etc. Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology,
Fecha de publicación distribución etc. 2015
300 ## - DESCRIPCIÓN FÍSICA
Extensión 45(3):286-93.
500 ## - NOTA GENERAL
Nota general Formato Vancouver:
Dröge L, Herraìz I, Zeisler H, Schlembach D, Stepan H, Küssel L et al. Maternal serum sFlt-1/PlGF ratio in twin pregnancies with and without pre-eclampsia in comparison with singleton pregnancies. Ultrasound Obstet Gynecol. 2015 Mar;45(3):286-93.
501 ## - NOTA DE “CON”
Nota de "Con" PMID: 25491901
504 ## - NOTA DE BIBLIOGRAFÍA; ETC.
Nota de bibliografía etc. Contiene 32 referencias
520 ## - NOTA DE SUMARIO; ETC.
Sumario etc. Objective: In singleton pregnancies, soluble fms-like tyrosine kinase-1 (sFlt-1), placental growth factor (PlGF) and the sFlt-1/PlGF ratio have shown utility as a diagnostic test for pre-eclampsia (PE). The objective of this study was to characterize the maternal serum levels of sFlt-1, PlGF and sFlt-1/PlGF ratio in normal and pre-eclamptic twin pregnancies.
Methods: In a European multicenter case-control study, 49 women with a twin pregnancy were enrolled, including 31 uneventful and 18 pre-eclamptic pregnancies. sFlt-1 and PlGF were measured and receiver-operating characteristics (ROC) analysis was performed. The median sFlt-1 and PlGF serum concentrations and sFlt-1/PlGF ratio were compared with those of a singleton cohort, matched for gestational age, with PE (n = 54) and with an uncomplicated pregnancy outcome (n = 238).
Results: In twin pregnancies with PE, sFlt-1 levels and the sFlt-1/PlGF ratio were increased and PlGF levels were decreased as compared with those of twin gestations with an uneventful pregnancy outcome (20 011.50 ± 2330.35 pg/mL vs 4503.00 ± 2012.05 pg/mL (P ≤ 0.001), 164.22 ± 31.35 vs 13.29 ± 319.64 (P ≤ 0.001), and 138.80 ± 20.04 pg/mL vs 403.00 ± 193.10 pg/mL (P ≤ 0.001), respectively). The sFlt-1/PlGF ratio did not differ between twin pregnancies with PE and singleton pregnancies with PE. In twin pregnancies with an uneventful outcome, sFlt-1 levels and sFlt-1/PlGF ratio were increased, but no differences in PlGF concentration were found when compared with that of singleton controls. ROC analysis determined 53 as an optimal cut-off of the sFlt-1/PlGF ratio for diagnosing PE in twin gestations, yielding a sensitivity of 94.4% and a specificity of 74.2%. The cut-off values established for singleton pregnancies, of 33 and 85, led to sensitivities of 100% and 83.3%, and specificities of 67.7% and 80.6%, when used to detect PE in twin pregnancies.
Conclusions: Significant differences in the serum marker levels in singleton vs twin pregnancies were detected. Reference ranges of sFlt-1, PlGF and their ratio in singleton pregnancies are therefore not transferable to twin pregnancies.
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD
9 (RLIN) 427
Nombre de entidad o nombre de jurisdicción como elemento inicial Servicio de Obstetricia y Ginecología
856 ## - LOCALIZACIÓN Y ACCESO ELECTRÓNICOS
Identificador Uniforme del Recurso (URI) http://pc-h12o-es.m-hdoct.a17.csinet.es/pdf/pc/1/pc17147.pdf
Acceso Solicitar documento
942 ## - ENTRADA PARA ELEMENTOS AGREGADOS (KOHA)
Fuente de clasificación o esquema de ordenación en estanterías
Koha [por defecto] tipo de item Artículo
Suprimido en OPAC Público
Existencias
Suprimido Estado de pérdida Fuente de clasificación o esquema de ordenación en estanterías Estropeado No para préstamo Localización permanente Localización actual Fecha de adquisición Signatura completa Fecha última consulta Fecha del precio de reemplazo Tipo de item de Koha
          Hospital Universitario 12 de Octubre Hospital Universitario 12 de Octubre 2023-01-24 PC17147 2023-01-24 2023-01-24 Artículo

Con tecnología Koha