Biblioteca Hospital 12 de Octubre

Magnetic-Responsive Release Controlled by Hot Spot Effect. (Registro nro. 17139)

000 -CABECERA
Campo de control de longitud fija nab a22 7a 4500
003 - IDENTIFICADOR DEL NÚMERO DE CONTROL
Campo de control PC17139
005 - FECHA Y HORA DE LA ÚLTIMA TRANSACCIÓN
Campo de control 20230123131456.0
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA
Campo de control de longitud fija 230123b xxu||||| |||| 00| 0 eng d
040 ## - FUENTE DE LA CATALOGACIÓN
Centro transcriptor H12O
041 ## - CÓDIGO DE LENGUA
Código de lengua del texto/banda sonora o título independiente eng
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 3126
Nombre de persona Guisasola, Eduardo
Término indicativo de función Instituto de Investigación imas12
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 2995
Nombre de persona Baeza, Alejandro
Término indicativo de función Instituto de Investigación imas12
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 3127
Nombre de persona Talelli, Marina
Término indicativo de función Instituto de Investigación imas12
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 2843
Nombre de persona Arcos, Daniel
Término indicativo de función Instituto de Investigación imas12
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 2644
Nombre de persona Vallet Regí, María
Término indicativo de función Instituto de Investigación imas12
245 00 - MENCIÓN DE TÍTULO
Título Magnetic-Responsive Release Controlled by Hot Spot Effect.
Tipo de material [artículo]
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Nombre del editor distribuidor etc. Langmuir : the ACS journal of surfaces and colloids,
Fecha de publicación distribución etc. 2015
300 ## - DESCRIPCIÓN FÍSICA
Extensión 31(46):12777-82.
500 ## - NOTA GENERAL
Nota general Formato Vancouver:
Guisasola E, Baeza A, Talelli M, Arcos D, Moros M, de la Fuente JM et al. Magnetic-Responsive Release Controlled by Hot Spot Effect. Langmuir. 2015 Nov 24;31(46):12777-82.
501 ## - NOTA DE “CON”
Nota de "Con" PMID: 26536300
504 ## - NOTA DE BIBLIOGRAFÍA; ETC.
Nota de bibliografía etc. Contiene 31 referencias
520 ## - NOTA DE SUMARIO; ETC.
Sumario etc. Magnetically triggered drug delivery nanodevices have attracted great attention in nanomedicine, as they can feature as smart carriers releasing their payload at clinician's will. The key principle of these devices is based on the properties of magnetic cores to generate thermal energy in the presence of an alternating magnetic field. Then, the temperature increase triggers the drug release. Despite this potential, the rapid heat dissipation in living tissues is a serious hindrance for their clinical application. It is hypothesized that magnetic cores could act as hot spots, this is, produce enough heat to trigger the release without the necessity to increase the global temperature. Herein, a nanocarrier has been designed to respond when the temperature reaches 43 °C. This material has been able to release its payload under an alternating magnetic field without the need of increasing the global temperature of the environment, proving the efficacy of the hot spot mechanism in magnetic-responsive drug delivery devices.
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD
9 (RLIN) 625
Nombre de entidad o nombre de jurisdicción como elemento inicial Instituto de Investigación imas12
856 ## - LOCALIZACIÓN Y ACCESO ELECTRÓNICOS
Identificador Uniforme del Recurso (URI) http://pc-h12o-es.m-hdoct.a17.csinet.es/pdf/pc/1/pc17139.pdf
Acceso Solicitar documento
942 ## - ENTRADA PARA ELEMENTOS AGREGADOS (KOHA)
Fuente de clasificación o esquema de ordenación en estanterías
Koha [por defecto] tipo de item Artículo
Suprimido en OPAC Público
Existencias
Suprimido Estado de pérdida Fuente de clasificación o esquema de ordenación en estanterías Estropeado No para préstamo Localización permanente Localización actual Fecha de adquisición Signatura completa Fecha última consulta Fecha del precio de reemplazo Tipo de item de Koha
          Hospital Universitario 12 de Octubre Hospital Universitario 12 de Octubre 2023-01-23 PC17139 2023-01-23 2023-01-23 Artículo

Con tecnología Koha