Biblioteca Hospital 12 de Octubre

Resonancia magnética sin sedación en recién nacidos. (Registro nro. 17138)

000 -CABECERA
Campo de control de longitud fija nab a22 7a 4500
003 - IDENTIFICADOR DEL NÚMERO DE CONTROL
Campo de control PC17138
005 - FECHA Y HORA DE LA ÚLTIMA TRANSACCIÓN
Campo de control 20230123124524.0
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA
Campo de control de longitud fija 230123b xxu||||| |||| 00| 0 eng d
040 ## - FUENTE DE LA CATALOGACIÓN
Centro transcriptor H12O
041 ## - CÓDIGO DE LENGUA
Código de lengua del texto/banda sonora o título independiente spa
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 1426
Nombre de persona Ureta Velasco, Noelia
Término indicativo de función Neonatología
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 1850
Nombre de persona Martínez de Aragón Calvo, Ana
Término indicativo de función Radiodiagnóstico
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 1848
Nombre de persona Moral Pumarega, María Teresa
Término indicativo de función Neonatología
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 1433
Nombre de persona Núñez Enamorado, Noemí
Término indicativo de función Pediatría
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 1851
Nombre de persona Bergón Sendín, Elena
Término indicativo de función Neonatología
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 1008
Nombre de persona Pallás Alonso, Carmen Rosa
Término indicativo de función Neonatología
245 00 - MENCIÓN DE TÍTULO
Título Resonancia magnética sin sedación en recién nacidos.
Tipo de material [artículo]
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Nombre del editor distribuidor etc. Anales de pediatría : publicación oficial de la Asociación Española de Pediatría (A.E.P.),
Fecha de publicación distribución etc. 2015
300 ## - DESCRIPCIÓN FÍSICA
Extensión 82(5):354-9.
500 ## - NOTA GENERAL
Nota general Formato Vancouver:
Ureta Velasco N, Martínez de Aragón A, Moral Pumarega MT, Núñez Enamorado N, Bergón Sendín E, Pallás Alonso CR. Resonancia magnética sin sedación en recién nacidos.
An Pediatr (Barc). 2015 May;82(5):354-9.
501 ## - NOTA DE “CON”
Nota de "Con" PMID: 25001372
504 ## - NOTA DE BIBLIOGRAFÍA; ETC.
Nota de bibliografía etc. Contiene 12 referencias
520 ## - NOTA DE SUMARIO; ETC.
Sumario etc. Introduction: The ability to perform magnetic resonance imaging (MRI) without sedation in the neonatal period increases patient safety, availability and profitability of the diagnostic tool. The aim in this study was to evaluate a new protocol of MRI without sedation during a 20-month period. In the protocol, the patients are prepared in the neonatal unit.
Patients and method: Prospective descriptive study, from May 2012 to December 2013. Patients included were neonates requiring MRI, clinically stable and not requiring ventilatory support. The method was based on the application of developmental centered care and the use of a vacuum matress to immobilize the baby. The principal outcome parameter of interest was the percentage of succesfully completed MRIs. The duration of the MRI and the number of interruptions, was also studied from October 2012.
Results: A total of 43 MRIs without sedation were carried out on 42 patients: 41 cerebral and 2 spinal. The success rate was 97.7% (42/43). The mean MRI time was 26.3 minutes (95% CI 23.3-29.3 mins; range 16-50 mins). MRIs were completed without interruption in 20 of the 34 cases (58%) in which the duration was recorded. The number of interruptions per procedure varied from 0 to 3, with a mean of 0.6 (95% CI 0.3-0.8) and a median of 0.
Conclusion: The protocol had a success rate of over 90%. Thus MRI without sedation seems applicable in Spanish hospitals, with most of the preparation being performed in the neonatal unit, in order to reduce the occupation of the MRI unit, as well as minimizing stress to the baby.
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD
9 (RLIN) 793
Nombre de entidad o nombre de jurisdicción como elemento inicial Servicio de Neonatología
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD
9 (RLIN) 462
Nombre de entidad o nombre de jurisdicción como elemento inicial Servicio de Radiodiagnóstico
856 ## - LOCALIZACIÓN Y ACCESO ELECTRÓNICOS
Identificador Uniforme del Recurso (URI) http://pc-h12o-es.m-hdoct.a17.csinet.es/pdf/pc/1/pc17138.pdf
Acceso Solicitar documento
942 ## - ENTRADA PARA ELEMENTOS AGREGADOS (KOHA)
Fuente de clasificación o esquema de ordenación en estanterías
Koha [por defecto] tipo de item Artículo
Suprimido en OPAC Público
Existencias
Suprimido Estado de pérdida Fuente de clasificación o esquema de ordenación en estanterías Estropeado No para préstamo Localización permanente Localización actual Fecha de adquisición Signatura completa Fecha última consulta Fecha del precio de reemplazo Tipo de item de Koha
          Hospital Universitario 12 de Octubre Hospital Universitario 12 de Octubre 2023-01-23 PC17138 2023-01-23 2023-01-23 Artículo

Con tecnología Koha