Detección de efectos adversos en cirugía general mediante la aplicación de la metodología «Trigger Tool». (Registro nro. 16919)
[ vista simple ]
000 -CABECERA | |
---|---|
Campo de control de longitud fija | nab a22 7a 4500 |
003 - IDENTIFICADOR DEL NÚMERO DE CONTROL | |
Campo de control | PC16919 |
005 - FECHA Y HORA DE LA ÚLTIMA TRANSACCIÓN | |
Campo de control | 20220620140959.0 |
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA | |
Campo de control de longitud fija | 220620b xxu||||| |||| 00| 0 eng d |
040 ## - FUENTE DE LA CATALOGACIÓN | |
Centro transcriptor | H12O |
041 ## - CÓDIGO DE LENGUA | |
Código de lengua del texto/banda sonora o título independiente | spa, eng |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 3070 |
Nombre de persona | Pérez Zapata, Ana Isabel |
Término indicativo de función | Cirugía General y del Aparato Digestivo |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 2966 |
Nombre de persona | Gutiérrez Samaniego, María |
Término indicativo de función | Cirugía General y Aparato Digestivo |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 2690 |
Nombre de persona | Rodríguez Cuéllar, Elías |
Término indicativo de función | Cirugía General y del Aparato Digestivo |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 1893 |
Nombre de persona | Andrés Esteban, Eva |
Término indicativo de función | Instituto de Investigación i+12 |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 1011 |
Nombre de persona | Gómez de la Cámara, Agustín |
Término indicativo de función | Epidemiología Clínica |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 1071 |
Nombre de persona | Ruiz López, Pedro |
Término indicativo de función | Unidad de Calidad |
245 00 - MENCIÓN DE TÍTULO | |
Título | Detección de efectos adversos en cirugía general mediante la aplicación de la metodología «Trigger Tool». |
Tipo de material | [artículo] |
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT) | |
Nombre del editor distribuidor etc. | Cirugía española, |
Fecha de publicación distribución etc. | 2015 |
300 ## - DESCRIPCIÓN FÍSICA | |
Extensión | 93(2):84-90. |
500 ## - NOTA GENERAL | |
Nota general | Formato Vancouver: Pérez Zapata AI, Gutiérrez Samaniego M, Rodríguez Cuéllar E, Andrés Esteban EM, Gómez de la Cámara A, Ruiz López P. Detección de efectos adversos en cirugía general mediante la aplicación de la metodología «Trigger Tool». Cir Esp. 2015 Feb;93(2):84-90. |
501 ## - NOTA DE “CON” | |
Nota de "Con" | PMID: 25443150 |
504 ## - NOTA DE BIBLIOGRAFÍA; ETC. | |
Nota de bibliografía etc. | Contiene 23 referncias |
520 ## - NOTA DE SUMARIO; ETC. | |
Sumario etc. | Introduction: Surgery is one of the high-risk areas for the occurrence of adverse events (AE). The purpose of this study is to know the percentage of hospitalisation-related AE that are detected by the «Global Trigger Tool» methodology in surgical patients, their characteristics and the tool validity. Material and methods: Retrospective, observational study on patients admitted to a general surgery department, who underwent a surgical operation in a third level hospital during the year 2012. The identification of AE was carried out by patient record review using an adaptation of «Global Trigger Tool» methodology. Once an AE was identified, a harm category was assigned, including the grade in which the AE could have been avoided and its relation with the surgical procedure. Results: The prevalence of AE was 36,8%. There were 0,5 AE per patient. 56,2% were deemed preventable. 69,3% were directly related to the surgical procedure. The tool had a sensitivity of 86% and a specificity of 93,6%. The positive predictive value was 89% and the negative predictive value 92%. Conclusions: Prevalence of AE is greater than the estimate of other studies. In most cases the AE detected were related to the surgical procedure and more than half were also preventable. The adapted «Global Trigger Tool» methodology has demonstrated to be highly effective and efficient for detecting AE in surgical patients, identifying all the serious AE with few false negative results. |
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD | |
9 (RLIN) | 271 |
Nombre de entidad o nombre de jurisdicción como elemento inicial | Servicio de Cirugía General y del Aparato Digestivo |
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD | |
9 (RLIN) | 625 |
Nombre de entidad o nombre de jurisdicción como elemento inicial | Instituto de Investigación imas12 |
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD | |
9 (RLIN) | 1020 |
Nombre de entidad o nombre de jurisdicción como elemento inicial | Unidad de Calidad Asistencial |
856 ## - LOCALIZACIÓN Y ACCESO ELECTRÓNICOS | |
Identificador Uniforme del Recurso (URI) | http://pc-h12o-es.m-hdoct.a17.csinet.es/pdf/pc/1/pc16919.pdf |
Acceso | Solicitar documento |
942 ## - ENTRADA PARA ELEMENTOS AGREGADOS (KOHA) | |
Fuente de clasificación o esquema de ordenación en estanterías | |
Koha [por defecto] tipo de item | Artículo |
Suprimido en OPAC | Público |
Suprimido | Estado de pérdida | Fuente de clasificación o esquema de ordenación en estanterías | Estropeado | No para préstamo | Localización permanente | Localización actual | Fecha de adquisición | Signatura completa | Fecha última consulta | Fecha del precio de reemplazo | Tipo de item de Koha |
---|---|---|---|---|---|---|---|---|---|---|---|
Hospital Universitario 12 de Octubre | Hospital Universitario 12 de Octubre | 2022-06-20 | PC16919 | 2022-06-20 | 2022-06-20 | Artículo |