Auditing of Monitoring and Respiratory Support Equipment in a Level III-C Neonatal Intensive Care Unit. (Registro nro. 16809)
[ vista simple ]
000 -CABECERA | |
---|---|
Campo de control de longitud fija | nab a22 7a 4500 |
003 - IDENTIFICADOR DEL NÚMERO DE CONTROL | |
Campo de control | PC16809 |
005 - FECHA Y HORA DE LA ÚLTIMA TRANSACCIÓN | |
Campo de control | 20220713062807.0 |
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA | |
Campo de control de longitud fija | 220419b xxu||||| |||| 00| 0 eng d |
040 ## - FUENTE DE LA CATALOGACIÓN | |
Centro transcriptor | H12O |
041 ## - CÓDIGO DE LENGUA | |
Código de lengua del texto/banda sonora o título independiente | eng |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 1851 |
Nombre de persona | Bergón Sendín, Elena |
Término indicativo de función | Neonatología |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 814 |
Nombre de persona | Pérez Grande, María del Carmen |
Término indicativo de función | Pediatría |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 821 |
Nombre de persona | Lora Pablos, David |
Término indicativo de función | Instituto Investigación I+12 |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 1783 |
Nombre de persona | Cruz Bértolo, Javier de la |
Término indicativo de función | Epidemiología Clínica |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 1848 |
Nombre de persona | Moral Pumarega, María Teresa |
Término indicativo de función | Neonatología |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 1378 |
Nombre de persona | Bustos Lozano, Gerardo |
Término indicativo de función | Neonatología |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 1008 |
Nombre de persona | Pallás Alonso, Carmen Rosa |
Término indicativo de función | Neonatología |
245 00 - MENCIÓN DE TÍTULO | |
Título | Auditing of Monitoring and Respiratory Support Equipment in a Level III-C Neonatal Intensive Care Unit. |
Tipo de material | [artículo] |
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT) | |
Nombre del editor distribuidor etc. | BioMed research international, |
Fecha de publicación distribución etc. | 2015 |
300 ## - DESCRIPCIÓN FÍSICA | |
Extensión | 719497 |
500 ## - NOTA GENERAL | |
Nota general | Formato Vancouver: Bergón Sendín E, Pérez Grande C, Lora Pablos D, De la Cruz Bertolo J, Moral Pumarega MT, Bustos Lozano G et al. Auditing of Monitoring and Respiratory Support Equipment in a Level III-C Neonatal Intensive Care Unit. Biomed Res Int. 2015;2015:719497. |
501 ## - NOTA DE “CON” | |
Nota de "Con" | PMID: 26558277 PMCID: PMC4628988 |
504 ## - NOTA DE BIBLIOGRAFÍA; ETC. | |
Nota de bibliografía etc. | Contiene 27 referencias |
520 ## - NOTA DE SUMARIO; ETC. | |
Sumario etc. | Background: Random safety audits (RSAs) are a safety tool but have not been widely used in hospitals. Objectives: To determine the frequency of proper use of equipment safety mechanisms in relation to monitoring and mechanical ventilation by performing RSAs. The study also determined whether factors related to the patient, time period, or characteristics of the area of admission influenced how the device safety systems were used. Methods: A prospective observational study was conducted in a level III-C Neonatal Intensive Care Unit (NICU) during 2012. 87 days were randomly selected. Appropriate overall use was defined when all evaluated variables were correctly programmed in the audited device. Results: A total of 383 monitor and ventilator audits were performed. The Kappa coefficient of interobserver agreement was 0.93. The rate of appropriate overall use of the monitors and respiratory support equipment was 33.68%. Significant differences were found with improved usage during weekends, OR 1.85 (1.12-3.06, p = 0.01), and during the late shift (3 pm to 10 pm), OR 1.59 (1.03-2.4, p = 0.03). Conclusions: Equipment safety systems of monitors and ventilators are not properly used. To improve patient safety, we should identify which alarms are really needed and where the difficulties lie for the correct alarm programming. |
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD | |
9 (RLIN) | 625 |
Nombre de entidad o nombre de jurisdicción como elemento inicial | Instituto de Investigación imas12 |
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD | |
9 (RLIN) | 446 |
Nombre de entidad o nombre de jurisdicción como elemento inicial | Servicio de Pediatría-Neonatología |
856 ## - LOCALIZACIÓN Y ACCESO ELECTRÓNICOS | |
Identificador Uniforme del Recurso (URI) | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4628988/ |
Acceso | Acceso libre |
942 ## - ENTRADA PARA ELEMENTOS AGREGADOS (KOHA) | |
Fuente de clasificación o esquema de ordenación en estanterías | |
Koha [por defecto] tipo de item | Artículo |
Suprimido en OPAC | Público |
Suprimido | Estado de pérdida | Fuente de clasificación o esquema de ordenación en estanterías | Estropeado | No para préstamo | Localización permanente | Localización actual | Fecha de adquisición | Signatura completa | Fecha última consulta | Fecha del precio de reemplazo | Tipo de item de Koha |
---|---|---|---|---|---|---|---|---|---|---|---|
Hospital Universitario 12 de Octubre | Hospital Universitario 12 de Octubre | 2022-04-19 | PC16809 | 2022-04-19 | 2022-04-19 | Artículo |