Biblioteca Hospital 12 de Octubre

A Prospective Randomized Trial of Drug-Eluting Balloons Versus Everolimus-Eluting Stents in Patients With In-Stent Restenosis of Drug-Eluting Stents: The RIBS IV Randomized Clinical Trial. (Registro nro. 16739)

000 -CABECERA
Campo de control de longitud fija nab a22 7a 4500
003 - IDENTIFICADOR DEL NÚMERO DE CONTROL
Campo de control PC16739
005 - FECHA Y HORA DE LA ÚLTIMA TRANSACCIÓN
Campo de control 20220302140746.0
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA
Campo de control de longitud fija 220302b xxu||||| |||| 00| 0 eng d
040 ## - FUENTE DE LA CATALOGACIÓN
Centro transcriptor H12O
041 ## - CÓDIGO DE LENGUA
Código de lengua del texto/banda sonora o título independiente eng
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 1241
Nombre de persona Velázquez Martín, María Teresa
Término indicativo de función Cardiología
245 02 - MENCIÓN DE TÍTULO
Título A Prospective Randomized Trial of Drug-Eluting Balloons Versus Everolimus-Eluting Stents in Patients With In-Stent Restenosis of Drug-Eluting Stents: The RIBS IV Randomized Clinical Trial.
Tipo de material [artículo]
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Nombre del editor distribuidor etc. Journal of the American College of Cardiology,
Fecha de publicación distribución etc. 2015
300 ## - DESCRIPCIÓN FÍSICA
Extensión 66(1):23-33.
500 ## - NOTA GENERAL
Nota general Formato Vancouver:
Alfonso F, Pérez Vizcayno MJ, Cárdenas A, García del Blanco B, García Touchard A, López-Minguéz JR et al; RIBS IV Study Investigators (under auspices of Interventional Cardiology Working Group of Spanish Society of Cardiology). A Prospective Randomized Trial of Drug-Eluting Balloons Versus Everolimus-Eluting Stents in Patients With In-Stent Restenosis of Drug-Eluting Stents: The RIBS IV Randomized Clinical Trial. J Am Coll Cardiol. 2015 Jul 7;66(1):23-33.
501 ## - NOTA DE “CON”
Nota de "Con" PMID: 26139054
504 ## - NOTA DE BIBLIOGRAFÍA; ETC.
Nota de bibliografía etc. Contiene 32 referencia
520 ## - NOTA DE SUMARIO; ETC.
Sumario etc. Background: Treatment of patients with drug-eluting stent (DES) in-stent restenosis (ISR) remains a major challenge.
Objectives: This study evaluated the comparative efficacy of drug-eluting balloons (DEB) and everolimus-eluting stents (EES) in patients presenting with DES-ISR.
Methods: The study design of this multicenter randomized clinical trial assumed superiority of EES for the primary endpoint, in-segment minimal lumen diameter at the 6- to 9-month angiographic follow-up.
Results: A total of 309 patients with DES-ISR from 23 Spanish university hospitals were randomly allocated to DEB (n = 154) or EES (n = 155). At late angiography (median 247 days; 90% of eligible patients), patients in the EES arm had a significantly larger minimal lumen diameter (2.03 ± 0.7 mm vs. 1.80 ± 0.6 mm; p < 0.01) (absolute mean difference: 0.23 mm; 95% CI: 0.07 to 0.38) [corrected], net lumen gain (1.28 ± 0.7 mm vs. 1.01 ± 0.7 mm; p < 0.01), and lower percent diameter stenosis (23 ± 22% vs. 30 ± 22%; p < 0.01) and binary restenosis rate (11% vs. 19%; p = 0.06), compared with patients in the DEB arm. Consistent results were observed in the in-lesion analysis. At the 1-year clinical follow-up (100% of patients), the main clinical outcome measure (composite of cardiac death, myocardial infarction, and target vessel revascularization) was significantly reduced in the EES arm (10% vs. 18%; p = 0.04; hazard ratio: 0.58; 95% CI: 0.35 to 0.98), mainly driven by a lower need for target vessel revascularization (8% vs. 16%; p = 0.035).

Conclusions: In patients with DES-ISR, EES provided superior long-term clinical and angiographic results compared with DEB. (Restenosis Intra-Stent of Drug-Eluting Stents: Drug-Eluting Balloon vs Everolimus-Eluting Stent [RIBS IV]; NCT01239940).
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD
9 (RLIN) 119
Nombre de entidad o nombre de jurisdicción como elemento inicial Servicio de Cardiología
856 ## - LOCALIZACIÓN Y ACCESO ELECTRÓNICOS
Identificador Uniforme del Recurso (URI) http://pc-h12o-es.m-hdoct.a17.csinet.es/pdf/pc/1/pc16739.pdf
Acceso Solicitar documento
942 ## - ENTRADA PARA ELEMENTOS AGREGADOS (KOHA)
Fuente de clasificación o esquema de ordenación en estanterías
Koha [por defecto] tipo de item Artículo
Suprimido en OPAC Público
Existencias
Suprimido Estado de pérdida Fuente de clasificación o esquema de ordenación en estanterías Estropeado No para préstamo Localización permanente Localización actual Fecha de adquisición Signatura completa Fecha última consulta Fecha del precio de reemplazo Tipo de item de Koha
          Hospital Universitario 12 de Octubre Hospital Universitario 12 de Octubre 2022-03-02 PC16739 2022-03-02 2022-03-02 Artículo

Con tecnología Koha