Uterine artery Doppler and sFlt-1/PlGF ratio: prognostic value in early-onset pre-eclampsia. (Registro nro. 16693)

000 -CABECERA
Campo de control de longitud fija nab a22 7a 4500
003 - IDENTIFICADOR DEL NÚMERO DE CONTROL
Campo de control PC16693
005 - FECHA Y HORA DE LA ÚLTIMA TRANSACCIÓN
Campo de control 20211217121556.0
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA
Campo de control de longitud fija 211217b xxu||||| |||| 00| 0 eng d
040 ## - FUENTE DE LA CATALOGACIÓN
Centro transcriptor H12O
041 ## - CÓDIGO DE LENGUA
Código de lengua del texto/banda sonora o título independiente eng
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 2003
Nombre de persona Gómez Arriaga, Paula Isabel
Término indicativo de función Obstetricia y Ginecología
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 894
Nombre de persona Herráiz García, Ignacio
Término indicativo de función Obstetricia y Ginecología
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 895
Nombre de persona Escribano Abad, David
Término indicativo de función Obstetricia y Ginecología
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 896
Nombre de persona Galindo Izquierdo, Alberto
Término indicativo de función Obstetricia y Ginecología
245 00 - MENCIÓN DE TÍTULO
Título Uterine artery Doppler and sFlt-1/PlGF ratio: prognostic value in early-onset pre-eclampsia.
Tipo de material [artículo]
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Nombre del editor distribuidor etc. Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology.
Fecha de publicación distribución etc. 2014
300 ## - DESCRIPCIÓN FÍSICA
Extensión 43(5):525-32.
500 ## - NOTA GENERAL
Nota general Formato Vancouver:
Gómez Arriaga PI, Herráiz I, López Jiménez EA, Escribano D, Denk B, Galindo A. Uterine artery Doppler and sFlt-1/PlGF ratio: prognostic value in early-onset pre-eclampsia. Ultrasound Obstet Gynecol. 2014 May;43(5):525-32.
501 ## - NOTA DE “CON”
Nota de "Con" PMID: 24185845
504 ## - NOTA DE BIBLIOGRAFÍA; ETC.
Nota de bibliografía etc. Contiene 24 referencias
520 ## - NOTA DE SUMARIO; ETC.
Sumario etc. Objective: To evaluate the performance of the mean uterine artery pulsatility index (UtA-PI) and the automated measurement of the soluble fms-like tyrosine kinase-1 (sFlt-1)/placental growth factor (PlGF) ratio for the prognostic assessment of both maternal and perinatal outcomes, and the time-to-delivery interval in early-onset (≤ 34 + 0 weeks) pre-eclampsia (PE) cases with attempted expectant management.
Methods: Fifty-one singleton pregnancies with early-onset PE were enrolled in the study. Mean UtA-PI and sFlt/PlGF ratio were measured at diagnosis. The association of each marker and their combinations with adverse maternal and perinatal outcomes was assessed by univariable comparisons and multivariable logistic regression analysis and time-to-delivery interval by survival analysis.
Results: Twenty-six (51%) had adverse maternal outcome and 14 (27%) had adverse perinatal outcome. At the time of onset of PE, only gestational age was significantly related to maternal complications. Gestational age at onset, mean UtA-PI and sFlt-1/PlGF ratio were significantly associated with perinatal complications, their combination reaching a sensitivity of 64% with 95% specificity, and an area under the receiver-operating characteristics curve of 0.89 (95% CI, 0.79-0.99). Regarding the time until delivery, 92% (12/13) of cases with sFlt-1/PlGF ratio > 655 and 39% (15/38) of cases with a ratio ≤ 655 delivered within the first 48 h, 8% (1/13) and 19% (7/38), respectively, delivered between 48 h and 7 days and 0% (0/13) and 42% (16/38), respectively, delivered after 7 days.
Conclusion: Mean UtA-PI and sFlt-1/PlGF ratio in combination with gestational age are useful for the prognostic assessment of perinatal complications at the time of diagnosis of early-onset PE, but this combination has limited value for the prediction of maternal complications. Moreover, sFlt-1/PlGF ratio > 655 is closely related to the need to deliver within 48 h. [[ArtCopyrightmsg]].
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD
9 (RLIN) 427
Nombre de entidad o nombre de jurisdicción como elemento inicial Servicio de Obstetricia y Ginecología
856 ## - LOCALIZACIÓN Y ACCESO ELECTRÓNICOS
Identificador Uniforme del Recurso (URI) http://pc-h12o-es.m-hdoct.a17.csinet.es/pdf/pc/1/pc16693.pdf
Acceso Solicitar documento
942 ## - ENTRADA PARA ELEMENTOS AGREGADOS (KOHA)
Fuente de clasificación o esquema de ordenación en estanterías
Koha [por defecto] tipo de item Artículo
Suprimido en OPAC Público
Existencias
Suprimido Estado de pérdida Fuente de clasificación o esquema de ordenación en estanterías Estropeado No para préstamo Localización permanente Localización actual Fecha de adquisición Signatura completa Fecha última consulta Fecha del precio de reemplazo Tipo de item de Koha
          Hospital Universitario 12 de Octubre Hospital Universitario 12 de Octubre 2021-12-17 PC16693 2021-12-17 2021-12-17 Artículo

Con tecnología Koha