Impact of short-term mechanical circulatory support with extracorporeal devices on postoperative outcomes after emergency heart transplantation: data from a multi-institutional Spanish cohort. (Registro nro. 16339)
[ vista simple ]
000 -CABECERA | |
---|---|
Campo de control de longitud fija | nab a22 7a 4500 |
003 - IDENTIFICADOR DEL NÚMERO DE CONTROL | |
Campo de control | PC16339 |
005 - FECHA Y HORA DE LA ÚLTIMA TRANSACCIÓN | |
Campo de control | 20210706062659.0 |
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA | |
Campo de control de longitud fija | 210331b xxu||||| |||| 00| 0 eng d |
040 ## - FUENTE DE LA CATALOGACIÓN | |
Centro transcriptor | H12O |
041 ## - CÓDIGO DE LENGUA | |
Código de lengua del texto/banda sonora o título independiente | eng |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 1250 |
Nombre de persona | Delgado Jiménez, Juan Francisco |
Término indicativo de función | Cardiología |
245 00 - MENCIÓN DE TÍTULO | |
Título | Impact of short-term mechanical circulatory support with extracorporeal devices on postoperative outcomes after emergency heart transplantation: data from a multi-institutional Spanish cohort. |
Tipo de material | [artículo] |
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT) | |
Nombre del editor distribuidor etc. | International journal of cardiology, |
Fecha de publicación distribución etc. | 2014 |
300 ## - DESCRIPCIÓN FÍSICA | |
Extensión | 176(1):86-93. |
500 ## - NOTA GENERAL | |
Nota general | Formato Vancouver: Barge-Caballero E, Almenar-Bonet L, Villa-Arranz A, Pérez-Villa F, Segovia-Cubero J, Delgado-Jiménez J et al. Impact of short-term mechanical circulatory support with extracorporeal devices on postoperative outcomes after emergency heart transplantation: data from a multi-institutional Spanish cohort. Int J Cardiol. 2014 Sep;176(1):86-93. |
501 ## - NOTA DE “CON” | |
Nota de "Con" | PMID: 25034802 |
504 ## - NOTA DE BIBLIOGRAFÍA; ETC. | |
Nota de bibliografía etc. | Contiene 19 referencias |
520 ## - NOTA DE SUMARIO; ETC. | |
Sumario etc. | Objectives: We sought to investigate the potential impact of preoperative short-term mechanical circulatory support (MCS) with extracorporeal devices on postoperative outcomes after emergency heart transplantation (HT). Methods: We conducted an observational study of 669 patients who underwent emergency HT in 15 Spanish hospitals between 2000 and 2009. Postoperative outcomes of patients bridged to HT on short-term MCS (n=101) were compared with those of the rest of the cohort (n=568). Short-term MCS included veno-arterial extracorporeal membrane oxygenators (VA-ECMOs, n=23), and both pulsatile-flow (n=53) and continuous-flow (n=25) extracorporeal ventricular assist devices (VADs). No patient underwent HT on intracorporeal VADs. Results: Preoperative short-term MCS was independently associated with increased in-hospital postoperative mortality (adjusted odds-ratio 1.75, 95% CI 1.05-2.91) and overall post-transplant mortality (adjusted hazard-ratio 1.60, 95% CI 1.15-2.23). Rates of major surgical bleeding, cardiac reoperation, postoperative infection and primary graft failure were also significantly higher among MCS patients. Causes of death and survival after hospital discharge were similar in MCS and non-MCS candidates. Increased risk of post-transplant mortality affected patients bridged on pulsatile-flow extracorporeal VADs (adjusted hazard-ratio 2.21, 95% CI 1.48-3.30) and continuous-flow extracorporeal VADs (adjusted hazard-ratio 2.24, 95% CI 1.20-4.19), but not those bridged on VA-ECMO (adjusted hazard-ratio 0.51, 95% CI 0.21-1.25). Conclusions: Patients bridged to emergency HT on short-term MCS are exposed to an increased risk of postoperative complications and mortality. In our series, preoperative bridging with VA-ECMO resulted in comparable post-transplant outcomes to those of patients transplanted on conventional support. |
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD | |
9 (RLIN) | 119 |
Nombre de entidad o nombre de jurisdicción como elemento inicial | Servicio de Cardiología |
856 ## - LOCALIZACIÓN Y ACCESO ELECTRÓNICOS | |
Identificador Uniforme del Recurso (URI) | http://pc-h12o-es.m-hdoct.a17.csinet.es/pdf/pc/1/pc16339.pdf |
Acceso | Solicitar documento |
942 ## - ENTRADA PARA ELEMENTOS AGREGADOS (KOHA) | |
Fuente de clasificación o esquema de ordenación en estanterías | |
Koha [por defecto] tipo de item | Artículo |
Suprimido en OPAC | Público |
Suprimido | Estado de pérdida | Fuente de clasificación o esquema de ordenación en estanterías | Estropeado | No para préstamo | Localización permanente | Localización actual | Fecha de adquisición | Signatura completa | Fecha última consulta | Fecha del precio de reemplazo | Tipo de item de Koha |
---|---|---|---|---|---|---|---|---|---|---|---|
Hospital Universitario 12 de Octubre | Hospital Universitario 12 de Octubre | 2021-03-31 | PC16339 | 2021-03-31 | 2021-03-31 | Artículo |