Comparison of several functional methods to evaluate the immune response on stable kidney transplant patients. (Registro nro. 15991)
[ vista simple ]
000 -CABECERA | |
---|---|
Campo de control de longitud fija | nab a22 4500 |
003 - IDENTIFICADOR DEL NÚMERO DE CONTROL | |
Campo de control | PC15991 |
005 - FECHA Y HORA DE LA ÚLTIMA TRANSACCIÓN | |
Campo de control | 20210625062817.0 |
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA | |
Campo de control de longitud fija | 200615b xxu||||| |||| 00| 0 eng d |
040 ## - FUENTE DE LA CATALOGACIÓN | |
Centro transcriptor | H12O |
041 ## - CÓDIGO DE LENGUA | |
Código de lengua del texto/banda sonora o título independiente | eng |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 2597 |
Nombre de persona | Martinez-Flores, Jose A. |
Término indicativo de función | Instituto de Investigación i+12 |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 2598 |
Nombre de persona | Serrano, Manuel |
Término indicativo de función | Instituto de Investigación i+12 |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 393 |
Nombre de persona | Morales Pérez, Pablo |
Término indicativo de función | Inmunología |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 1510 |
Nombre de persona | Paz Artal, Estela |
Término indicativo de función | Inmunología |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 576 |
Nombre de persona | Morales Cerdán, José María |
Término indicativo de función | Nefrología |
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA | |
9 (RLIN) | 661 |
Nombre de persona | Serrano Hernández, Antonio |
Término indicativo de función | Inmunología |
245 00 - MENCIÓN DE TÍTULO | |
Título | Comparison of several functional methods to evaluate the immune response on stable kidney transplant patients. |
Tipo de material | [artículo] |
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT) | |
Nombre del editor distribuidor etc. | Journal of immunological methods, |
Fecha de publicación distribución etc. | 2014 |
300 ## - DESCRIPCIÓN FÍSICA | |
Extensión | 403(1-2):62-5. |
500 ## - NOTA GENERAL | |
Nota general | Formato Vancouver: Martínez-Flores JA, Serrano M, Morales P, Paz-Artal E, Morales JM, Serrano A. Comparison of several functional methods to evaluate the immune response on stable kidney transplant patients. J Immunol Methods. 2014 Jan 31;403(1-2):62-5. |
501 ## - NOTA DE “CON” | |
Nota de "Con" | PMID: 24291342 |
504 ## - NOTA DE BIBLIOGRAFÍA; ETC. | |
Nota de bibliografía etc. | Contiene 23 referencias |
520 ## - NOTA DE SUMARIO; ETC. | |
Sumario etc. | The introduction of new immunosuppressive drugs in the last two decades has been associated with a significant decline in the prevalence of acute rejection and a huge improvement of graft survival. Monitoring blood levels of immunosuppressive drugs is the most common way to control drug doses in renal transplant patients. This approach is useful and widely used but doesn't give accurate information about the immune status of the patient. For this goal, there are many "in house" protocols which give more information, but cannot be standardized, limiting their applicability to compare results between different laboratories. In this study we compare three classical functional methods to evaluate the immune response: Mixed lymphocyte reaction (MLR), phytohemagglutinin stimulated peripheral blood lymphocytes (PBLs), and anti-CD3 monoclonal antibodies (mAbs) against PBL with the only FDA-labeled assay to measure the patient immune status: Cylex ImmuKnow® that measures the intracelullar ATP in CD4+ lymphocytes. We used n=111 stable renal transplant patients, all the patients with more than one year functioning grafts. We referred the results to a control population of healthy blood donors (n=125). Results: Measurement of intracellular ATP in CD4+ lymphocytes is able to differentiate immunosuppressed populations in renal transplant patients from health controls (242.30±21.62 vs. 386.43±25.12, p 0.0001). By contrary, there were no differences between controls and renal recipients when functional response was measured by MLR, PHA and anti-CD3 mAbs (2.48±0.45 vs. 2.37±0.41; 2.84±0.76 vs. 2.37±0.32; 2.32±0.34 vs. 1.89±0.38 respectively). In summary, our results show that the measurement of ATP in CD4+ lymphocytes gives more accurate information in comparison to the classical methods. |
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD | |
9 (RLIN) | 625 |
Nombre de entidad o nombre de jurisdicción como elemento inicial | Instituto de Investigación imas12 |
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD | |
9 (RLIN) | 395 |
Nombre de entidad o nombre de jurisdicción como elemento inicial | Servicio de Inmunología |
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD | |
9 (RLIN) | 86 |
Nombre de entidad o nombre de jurisdicción como elemento inicial | Servicio de Nefrología |
856 ## - LOCALIZACIÓN Y ACCESO ELECTRÓNICOS | |
Identificador Uniforme del Recurso (URI) | http://pc-h12o-es.m-hdoct.a17.csinet.es/pdf/pc/1/pc15991.pdf |
Acceso | Solicitar documento |
942 ## - ENTRADA PARA ELEMENTOS AGREGADOS (KOHA) | |
Fuente de clasificación o esquema de ordenación en estanterías | |
Koha [por defecto] tipo de item | Artículo |
Suprimido en OPAC | Público |
Suprimido | Estado de pérdida | Fuente de clasificación o esquema de ordenación en estanterías | Estropeado | No para préstamo | Localización permanente | Localización actual | Fecha de adquisición | Signatura completa | Fecha última consulta | Fecha del precio de reemplazo | Tipo de item de Koha |
---|---|---|---|---|---|---|---|---|---|---|---|
Hospital Universitario 12 de Octubre | Hospital Universitario 12 de Octubre | 2020-06-15 | PC15991 | 2020-06-15 | 2020-06-15 | Artículo |