Biblioteca Hospital 12 de Octubre

Comparison of several functional methods to evaluate the immune response on stable kidney transplant patients. (Registro nro. 15991)

000 -CABECERA
Campo de control de longitud fija nab a22 4500
003 - IDENTIFICADOR DEL NÚMERO DE CONTROL
Campo de control PC15991
005 - FECHA Y HORA DE LA ÚLTIMA TRANSACCIÓN
Campo de control 20210625062817.0
008 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA
Campo de control de longitud fija 200615b xxu||||| |||| 00| 0 eng d
040 ## - FUENTE DE LA CATALOGACIÓN
Centro transcriptor H12O
041 ## - CÓDIGO DE LENGUA
Código de lengua del texto/banda sonora o título independiente eng
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 2597
Nombre de persona Martinez-Flores, Jose A.
Término indicativo de función Instituto de Investigación i+12
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 2598
Nombre de persona Serrano, Manuel
Término indicativo de función Instituto de Investigación i+12
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 393
Nombre de persona Morales Pérez, Pablo
Término indicativo de función Inmunología
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 1510
Nombre de persona Paz Artal, Estela
Término indicativo de función Inmunología
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 576
Nombre de persona Morales Cerdán, José María
Término indicativo de función Nefrología
100 ## - PUNTO DE ACCESO PRINCIPAL - NOMBRE DE PERSONA
9 (RLIN) 661
Nombre de persona Serrano Hernández, Antonio
Término indicativo de función Inmunología
245 00 - MENCIÓN DE TÍTULO
Título Comparison of several functional methods to evaluate the immune response on stable kidney transplant patients.
Tipo de material [artículo]
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Nombre del editor distribuidor etc. Journal of immunological methods,
Fecha de publicación distribución etc. 2014
300 ## - DESCRIPCIÓN FÍSICA
Extensión 403(1-2):62-5.
500 ## - NOTA GENERAL
Nota general Formato Vancouver:
Martínez-Flores JA, Serrano M, Morales P, Paz-Artal E, Morales JM, Serrano A. Comparison of several functional methods to evaluate the immune response on stable kidney transplant patients. J Immunol Methods. 2014 Jan 31;403(1-2):62-5.
501 ## - NOTA DE “CON”
Nota de "Con" PMID: 24291342
504 ## - NOTA DE BIBLIOGRAFÍA; ETC.
Nota de bibliografía etc. Contiene 23 referencias
520 ## - NOTA DE SUMARIO; ETC.
Sumario etc. The introduction of new immunosuppressive drugs in the last two decades has been associated with a significant decline in the prevalence of acute rejection and a huge improvement of graft survival. Monitoring blood levels of immunosuppressive drugs is the most common way to control drug doses in renal transplant patients. This approach is useful and widely used but doesn't give accurate information about the immune status of the patient. For this goal, there are many "in house" protocols which give more information, but cannot be standardized, limiting their applicability to compare results between different laboratories. In this study we compare three classical functional methods to evaluate the immune response: Mixed lymphocyte reaction (MLR), phytohemagglutinin stimulated peripheral blood lymphocytes (PBLs), and anti-CD3 monoclonal antibodies (mAbs) against PBL with the only FDA-labeled assay to measure the patient immune status: Cylex ImmuKnow® that measures the intracelullar ATP in CD4+ lymphocytes. We used n=111 stable renal transplant patients, all the patients with more than one year functioning grafts. We referred the results to a control population of healthy blood donors (n=125).
Results: Measurement of intracellular ATP in CD4+ lymphocytes is able to differentiate immunosuppressed populations in renal transplant patients from health controls (242.30±21.62 vs. 386.43±25.12, p 0.0001). By contrary, there were no differences between controls and renal recipients when functional response was measured by MLR, PHA and anti-CD3 mAbs (2.48±0.45 vs. 2.37±0.41; 2.84±0.76 vs. 2.37±0.32; 2.32±0.34 vs. 1.89±0.38 respectively). In summary, our results show that the measurement of ATP in CD4+ lymphocytes gives more accurate information in comparison to the classical methods.
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD
9 (RLIN) 625
Nombre de entidad o nombre de jurisdicción como elemento inicial Instituto de Investigación imas12
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD
9 (RLIN) 395
Nombre de entidad o nombre de jurisdicción como elemento inicial Servicio de Inmunología
710 ## - PUNTO DE ACCESO ADICIONAL - NOMBRE DE ENTIDAD
9 (RLIN) 86
Nombre de entidad o nombre de jurisdicción como elemento inicial Servicio de Nefrología
856 ## - LOCALIZACIÓN Y ACCESO ELECTRÓNICOS
Identificador Uniforme del Recurso (URI) http://pc-h12o-es.m-hdoct.a17.csinet.es/pdf/pc/1/pc15991.pdf
Acceso Solicitar documento
942 ## - ENTRADA PARA ELEMENTOS AGREGADOS (KOHA)
Fuente de clasificación o esquema de ordenación en estanterías
Koha [por defecto] tipo de item Artículo
Suprimido en OPAC Público
Existencias
Suprimido Estado de pérdida Fuente de clasificación o esquema de ordenación en estanterías Estropeado No para préstamo Localización permanente Localización actual Fecha de adquisición Signatura completa Fecha última consulta Fecha del precio de reemplazo Tipo de item de Koha
          Hospital Universitario 12 de Octubre Hospital Universitario 12 de Octubre 2020-06-15 PC15991 2020-06-15 2020-06-15 Artículo

Con tecnología Koha